Social Sciences > QUESTIONS & ANSWERS > ICC Masonry Exam 2022 with complete solution (All)
ICC Masonry Exam 2022 with complete solution Which of the following is the standard specification for loadbearing concrete masonry units? -Answer- ASTM C 90; RCMCI 6th Edition, Section 2.2.1 W ... hich of the following grout admixtures is used to obtain a high slump with reduced water? -Answer- Super plasticizer; RCMCI 6th Edition, Section 2.11.6 Which of the following is the standard specification that autoclaved aerated concrete masonry units must conform to for the strength class specified in the contract documents? -Answer- ASTM C 1386; CI 530; Part 2, Section 2.3E. IBC 2103.3 Grout intended for use in the construction of engineered and empirically designed masonry structures must comply with -Answer- ASTM C 476; 2006 IBC 2103.12 The slump test for grout must be performed in accordance with -Answer- ASTM C 1019; ASTM - C1019-03 In what condition are grout specimens to be tested? -Answer- Damp; ASTM - 1019-03 When the prism test method is being utilized, how long must the prisms cure prior to being cut? -Answer- 28; 2006 IBC 2105.3.1 After construction and grouting, masonry test prisms should not be disturbed or moved for a minimum of -Answer- 48 hours; ASTM - C 1314, Section 5.10 When field sampling grout, the elapsed time between obtaining the first and final portions of the sample shall not be more than -Answer- 15 minutes; ASTM - C1019, Section 7.2.1 If mortar compression tests are required, how many tests per day are to be taken for the three successive work days at the start of the job? -Answer- 1; RCMCI 6th Edition, 3.2.4 Glass unit masonry shall not be laid at temperatures below -Answer- 60 degrees F; 2006 IBC 2104.3.2.1 What is the maximum mean daily temperature permitted before newly constructed masonry must be fog sprayed during curing? -Answer- 100 degrees F; 2006 IBC 2104.4.3 When the temperature is below 40 degrees F, newly constructed masonry must be covered with a weather resistant membrane for a minimum of -Answer- 24 hours; 2006 IBC 2104.3.3.3 After initial mixing, when the ambient temperature exceeds 90 degrees F with a wind velocity over 8 mph, mortar used in masonry construction must be discarded after -Answer- 2 hours; 2006 IBC 2104.4.2.1 Which type of unit masonry is required to be placed with head and bed joints solidly filled? -Answer- Glass; 2006 IBC 2104.1.2.4 Thin bed mortar joints used in laying autoclaved aerated concrete masonry units shall not exceed a thickness of -Answer- 1/16"; 2006 IBC 2104.1.2.6 When the ambient temperature exceeds 100 degrees F or exceeds 90 degrees F with a wind velocity over 8 mph, what is the maximum distance that mortar may be spread ahead of AAC masonry units? -Answer- 4'; RCMCI 6th Edition, Section 11.2.4, 2006 IBC 2104.4.2.1(5). [Show More]
Last updated: 3 years ago
Preview 1 out of 7 pages
Buy this document to get the full access instantly
Instant Download Access after purchase
Buy NowInstant download
We Accept:
Can't find what you want? Try our AI powered Search
Connected school, study & course
About the document
Uploaded On
Sep 14, 2022
Number of pages
7
Written in
All
This document has been written for:
Uploaded
Sep 14, 2022
Downloads
0
Views
158
Scholarfriends.com Online Platform by Browsegrades Inc. 651N South Broad St, Middletown DE. United States.
We're available through e-mail, Twitter, Facebook, and live chat.
FAQ
Questions? Leave a message!
Copyright © Scholarfriends · High quality services·