Buckling in a horizontal vinyl siding is generally caused by A. reflected light B. improper fastening C. condensation in the walls D. improper house wrap B. improper fastening At what level ... would water pressure within a single-family dwelling begin to be considered excessive and require correction? A. 60 psi B. 80 psi C. 100 psi D. 120 psi B. 80 psi A newer home with electric heat is being inspected. It has a below grade finished basement containing a bedroom. The inspector should look for a smoke alarm and A. an escape and rescue opening B. a carbon monoxide alarm C. a fire extinguisher D. a safety ladder A. an escape and rescue opening A swimming pool fence must prevent passage of a sphere that is larger than A. 2 inches B. 3 inches C. 4 inches D. 5 inches C. 4 inches 5. Refer to the photograph to answer this question What should an inspector recommend to the client regarding the conditions shown in relation to the downspout/rain leader? A. Nothing, the downspout is properly installed B. Gravel should be installed under the downspout C. The downspout should be moved away from the siding D. A contractor should evaluate the downspout and recommend repairs D. A contractor should evaluate the downspout and recommend repairs If water infiltration is suspected behind a finished surface. What tool would be the best choice to verify dampness? A. an infrared thermometer B. a pin-type moisture meter C. a non-contact moisture meter D. a digital camera C. a non-contact moisture meter Gas fired furnace heat exchangers most often fail from A. low temperatures B. lack of use C. improper gas pressure D. rust and metal fatigue D. rust and metal fatigue Relative Humidity (RH) is expressed as A. volume B. percentage C. capacity D. temperature B. percentage Connections of dissimilar metal in a plumbing system, such as galvanized steel pipe and copper pipe, will usually cause A. reduced water pressure B. decreased water quality C. glazed pipes D. electrolysis D. electrolysis A Ground fault circuit interrupter (GFCI) is a safety device that A. disconnects power when the ground to the outlet is faulty B. detects moisture and disconnects power in wet locations C. disconnects the power when sensing current leakage to the ground D. protects against electrical surges and voltage spikes C. disconnects the power when sensing current leakage to the ground An electrical system with a fuse on the neutral conductor and on the energized (hot) conductors A. is twice as safe as a system where only the energized (hot) conductors are fused B. should have the neutral conductor fuse sized to one half the normal ampacity for the circuit C. is overused up to 50% if used only for lighting D. is hazardous and should be corrected D. is hazardous and should be corrected To operate a central air conditioner, an electric clothes dryer, and an electric range, the ampacity of the service to the house has to be AT LEAST A. 100 amps at 120 volts B. 125 amps at 120 volts C. 60 amps at 240 volts D. 100 amps at 240 volts D. 100 amps at 240 volts A floor joist in a crawl space has been cut where the toilet drain passes through the floor. The joists are 2x6 spaced at 16" on center. The inspector should recommend that A. the buyer monitor the floor. Floor systems such as this have redundant framing and removal of one joist is insignificant B. a contractor should support the cut joist with new piers and posts from below C. the cut joist should be headed off to adjacent framing members to distribute the load D. a contractor be contacted to determine with is needed and make repairs D. a contractor be contacted to determine with is needed and make repairs Most problems with concrete are caused at the time of installation. What single factor causes the MOST problems? A. The concrete has insufficient thickness B. Too much water is added to the mix C. Too much Portland cement is in the mix D. The wrong kind of sand is in the mix B. Too much water is added to the mix Brick chimneys on older properties with oil heat sometimes curve above the roof line, with no visible cracks. Which is a possible cause of this curving? A. settlement of the chimney footing B. expansion of mortar C. absence of a cricket flashing at the roof D. lack of a rain cap on the flue B. expansion of mortar Which set of building terms do NOT belong together? A. cripple trimmer, purlin B. arch, header, lintel C. rafters, ceiling joists, trusses D. sheathing, flooring, decking A. cripple trimmer, purlin Which has the LEAST effect on the deflection of a dimension lumber floor system? A. joist width B. joist grade C. joist species D. joist spacing A. joist width [Show More]
Last updated: 2 years ago
Preview 1 out of 20 pages
Buy this document to get the full access instantly
Instant Download Access after purchase
Buy NowInstant download
We Accept:
Can't find what you want? Try our AI powered Search
Connected school, study & course
About the document
Uploaded On
Oct 13, 2022
Number of pages
20
Written in
This document has been written for:
Uploaded
Oct 13, 2022
Downloads
0
Views
91
In Scholarfriends, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.
We're available through e-mail, Twitter, Facebook, and live chat.
FAQ
Questions? Leave a message!
Copyright © Scholarfriends · High quality services·