Indication for arterial line placement? Correct Answer: Hemodynamic monitoring
Multiple blood samples
Diagnostic or interventional radiology procedures
Continuous cardiac output monitoring
What test must be preformed
...
Indication for arterial line placement? Correct Answer: Hemodynamic monitoring
Multiple blood samples
Diagnostic or interventional radiology procedures
Continuous cardiac output monitoring
What test must be preformed prior to an arterial line placement? Correct Answer: Allen's test
How often should a fast flush test be preformed? Correct Answer: Every 8 hours
After blood draws
If the hemodynamic status changes
When changing tubing
What are the most common sites for arterial line insertion? Correct Answer: Radial
Femoral
Axillary
Dorsalis Pedis
Brachial Arteries
Positioning for radial arterial line placement: Correct Answer: 30-60 degrees of dorsiflexion with the aid
of a roll of gauze and an armband.
Avoid hyperabduction of the thumb.
How often should the atrial line catheter be changed out? Correct Answer: Every 7 days
Causes of inaccuracy in arterial line readings: Correct Answer: Air bubbles in the catheter system
Failure to zero the transducer air-fluid interface
Blood in the catheter system
Blood clot at the catheter tip
Kinking of the tubing system
Catheter tip lodging against the arterial wall
Soft, compliant tubing
Long tubing
Too many stopckcks (>3)
What is the pathology of afterload? Correct Answer: The pressure in which the heart must pump
against in order to eject blood during systole.
Medications that reduce afterload/preload include? Correct Answer: Vasodilators
What is the pathology of preload? Correct Answer: The filling pressure of the heart at end of diastole.
What is systemic vascular resistance (SVR)? Correct Answer: Resistance the left ventricle must
overcome to open the aortic valve and eject a volume of blood into systemic circulation.
[Show More]