Fire Academy / SCBA
What is the first step a firefighter should perform before dawn in a self-contained breathing
apparatus - ✔✔Check the air supply in the SCBA unit
Recharging your cylinders can be done from a bank o
...
Fire Academy / SCBA
What is the first step a firefighter should perform before dawn in a self-contained breathing
apparatus - ✔✔Check the air supply in the SCBA unit
Recharging your cylinders can be done from a bank of large air cylinders this system is called
a____system - ✔✔Cascade
PASS is an acronym for___ safety system - ✔✔Personal alert
During search and rescue, inhaling heated gases can cause___ which can lead to death from
asphyxiation - ✔✔Pulmonary edema
Purpose of the barriers found in structural firefighting personal protective equipment is to -
✔✔Prevents fluid from transferring to the skin and acts as an insulating barrier
How long does it take for the pass device to alarm if the wearer becomes inactive - ✔✔30
seconds
The byproduct of the combustion of plastics and polyurethane foam that acts to prevent the body
from using oxygen at the cellular level is - ✔✔Hydrogen cyanide
Primary function of the bypass purge valve of the self-contained breathing apparatus is - ✔✔For
use of the regulator fails
Proper position of the bypass valve on positive pressure self-contained breathing apparatus under
normal conditions is - ✔✔Fully closed
Purpose of the pass device is to - ✔✔Sound an alarm if a firefighter is motionless for a set period
of time
Carbon composite cylinders must be hydrostatically tested every___years - ✔✔3-5
When feeling a self-contained breathing apparatus cylinder, the cylinder must be: - ✔✔Placed in
a fragmentation containment or other shielded device
Coupling on the high-pressure hose that is attached to the self-contained breathing apparatus
cylinder should be - ✔✔Hand tight
Self-contained breathing apparatus should be inspected - ✔✔After each use
When using positive pressure self-contained breathing apparatus, a poor seal between the
facepiece and the firefighters face is dangerous because it is - ✔✔Depleting the air supply more
quickly
Firefighters should make sure their personal protective equipment is dry before engaging and
structural firefighting because - ✔✔Water trapped in the fabric can cause steam burns in fire
conditions
Newer turn out coats are supplied with a loop to permit a rescuer to grab in drag a down
firefighter. This feature is called a - ✔✔Drag rescue device
Personal protective equipment provides a ____ level of protection two firefighters -
✔✔Minimum
The common problem in using the non-integrated pass device is due to - ✔✔Forgetting to turn
on the unit
The low alarm of the self contained breathing apparatus will sound when____ percent of the
cylinders air supply is remaining - ✔✔25
They closed circuit or rebreather type breathing apparatus uses a cylinder of___ in its operation -
✔✔Oxygen
Used to refill a cylinder firefighter running out of air - ✔✔Universal air rescue connection
When donating a self contained breathing apparatus, firefighters should check to ensure that the
cylinders is at what minimum specific percentage of its capacity of air? - ✔✔90 percent
Firefighters are susceptible to poisoning or irritation from carbon monoxide and through -
✔✔Inhalation
Bypass valve on a self-contained breathing apparatus is used - ✔✔For use if regulator fails
When tightening the straps on a self-contained breathing apparatus face piece, the____ straps
should always be tightened first - ✔✔Lower
Pass device or design to alert rescuers attempting to - ✔✔Locate downed firefighter
Some self contained breathing apparatus cylinders for fire service use are made out of -
✔✔Aluminum
An advantage of a facepiece nose cup is that it - ✔✔Helps control internal fogging
If apparatus sirens noise levels exceed___ Decibles, firefighters should wear hearing protection -
✔✔90
What type of self-contained breathing apparatus is most commonly used for structural
firefighting? - ✔✔Open-circuit
When should you Dawn personal protective equipment not dawned prior to mounting the
apparatus? - ✔✔After arriving at the incident scene
Atmosphere are classified as oxygen deficient when they fall below___percent oxygen - ✔✔19.5
When operating at any emergency scene, firefighters must wear - ✔✔Personal protection
equipment suitable to the incident
As the oxygen supply in any given area falls below____unconsciousness can occure - ✔✔9
Which type of breathing apparatus recycles three users exhale breathing air removing carbon
dioxide and adding supplemental oxygen - ✔✔Closed-circuit
Or, damaged, and deteriorated parts of the self-contained breathing apparatus must be replaced
according to - ✔✔Manufactures insructions
Steel and aluminum cylinders for breathing apparatus should be hydrostatically tested after
each___year period - ✔✔Five
Hydrostatically testing of cylinders is done to ensure - ✔✔The integrity of the cylinder
A fire departments comprehensive self contained breathing apparatus program should include -
✔✔Inspection of the SCBA at the beginning of the shift
Defective self contained breathing apparatus is cylinders unit should be - ✔✔Removed from
service
Hypoxia is - ✔✔A deficiency of oxygen
The___must be stamped or labeled on a compressed air cylinder - ✔✔Last hydrostatic test date
Following each use, the facepiece of a breathing apparatus should be cleaned by: - ✔✔Washing
with a mixture of warm water and approved disinfectant
[Show More]