Journeyman Electrician Exam Questions and Answers Graded A+

Document Content and Description Below

Journeyman Electrician Exam Questions and Answers Graded A+ Where K=12.9, what is the approximate voltage-drop on a circuit where an 80-ampere, 240-volt, single-phase load is supplied with size 3 A... WG copper conductors with THWN insulation, and placed 200 feet from a panelboard? *Chapter 9 tables, table 8 conductor properties (pg. 70-689) ✔Ans✔ 7.84 volts voltage-drop formula VD=2KID VD=2 x 12.9 x 80amps x 200ft. =7.84 CM 52.620 CM Given the following information, what is the maximum approximate distance a single-phase, 240-volt, 42-ampere load can be located from a panelboard? *copper conductors - K = 12.9 *size 8 AWG THWN/THHN conductors are used *limit voltage drop to 3% *Chapter 9 tables, table 8 conductor properties (pg. 70-689) ✔Ans✔ 50 feet Distance formula 1st. find allowable VD - 240volts x 3% = 7.2volts D=CM x VD D=16,510 x 7.2=118,872=109.7feet 2 x K X I 2 X 12.9 X 42 What is the minimum allowable trade size intermediate metal conduit (IMC) required to contain a total of ten (10) copper THW conductors in a 20ft run, five (5) size 1 AWG and five (5) size 3 AWG? *(Pg. 70-684) ✔Ans✔ 2-1/2 Inches size 1 AWG THW=.1901 sq. in. x 5=.9505 sq. in. size 3 AWG THW=.1134 SQ. IN. x 5=.537 sq. in. total=1.5175 sq. in. *NOTE: A trade size 2-1/2 in. IMC with an allowable 40% fill of 2.054 sq. in. should be selected. If more than 2 conductors are used in a tube of EMT conduit, the total interior area that can be filled is no more than ______ percent. *(Pg. 70-680) ✔Ans✔ 40% What is the maximum cross-sectional value that conduit nipples under 24 inches long may be filled? *(pg. 70-678) ✔Ans✔ 60% (4) Where conduit or tubing nipples having a maximum length not to exceed 600 mm (24 in.) are installed between boxes, cabinets, and similar enclosures, the nipples shall be permitted to be filled to 60% of their total cross-sectional area, and 310.15(B)(3)(a) adjustment factors need not apply to this condition True or False: The raceway fill limitations detailed in 300.17 will apply to coaxial cables. ✔Ans✔ False [Show More]

Last updated: 2 years ago

Preview 1 out of 14 pages

Buy Now

Instant download

We Accept:

We Accept
document-preview

Buy this document to get the full access instantly

Instant Download Access after purchase

Buy Now

Instant download

We Accept:

We Accept

Reviews( 0 )

$10.00

Buy Now

We Accept:

We Accept

Instant download

Can't find what you want? Try our AI powered Search

132
0

Document information


Connected school, study & course


About the document


Uploaded On

Feb 15, 2023

Number of pages

14

Written in

Seller


seller-icon
Crescent

Member since 2 years

10 Documents Sold

Reviews Received
0
0
2
0
0
Additional information

This document has been written for:

Uploaded

Feb 15, 2023

Downloads

 0

Views

 132

Document Keyword Tags


$10.00
What is Scholarfriends

In Scholarfriends, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Scholarfriends · High quality services·