CRCST exam Questions and correct answers
automated supply replenishment systems:
automatic endoscope reprocessors are not recommended for flexible endoscopes
automatic washers clean using a spray force action call
...
CRCST exam Questions and correct answers
automated supply replenishment systems:
automatic endoscope reprocessors are not recommended for flexible endoscopes
automatic washers clean using a spray force action called:
bacteria that require free oxygen are called BLANK bacteria
before an item can be placed in a liquid chemical sterile processing system they must be:
behavior relating to what is right and wrong relative to the standards of conduct for your profession are called:
biological test should be performed in an ethylene oxide sterilizer
BLANK are often pathogenic to humans because they grow best at body temperatures.
BLANK is defined as the state of being soiled or infected by contact with infectious organisms or other material.
blue stain on a scope, what is the reason?
blush or rainbow type stains are cause by BLANK in water.
body balance is regulated by fluid in
both AORN and the join commission recommend that:
bowie dick tests should be run in:
cellulosic materials cannot be processed in a/an central service technicians can protect patients by breaking the chain of infection.
central service technicians wear special attire referred to as BLANK to minimize their exposure to blood borne pathogens and other contaminants.
central service technicians who do not think they are being treated appropriately by their employer should:
chemical indicators are FDA BLANK devices
chemical indicators:
chemical messengers that travel through the body and act on larger organs.
class 3 medical devices are identified as high risk
compunds that contain a positive electrical charge and exhibit germicidal properties.
compounds that have a negative charge and form a large group of synthetic detergents.
considered a master gland because it helps control the activities of all other endocrine glands
creates and revises standards for processing water for irrigation
cretion of a new blood supply to an area of the heart with a clotted or blocked artery
deionized water is used for:
endoscope channels should be cleaned and then left moist for storage
endoscopes are often processed in a mechanical unit called:
endotracheal tubes and anesthesia breathing curcuits are examples of:
enforces laws relating to the transportation of medical wastes.
enhances the global competitiveness and quality of life by promoting standards and ensuring their integrity
equipment leasing and the rental differ in that:
equipment should be inspected for obvious hazards such as cracked or frayed electrical cords
ergonomic injuries
established national emissions standards for EO used by hospitals are regulated
everyone who may have contact with biohazard items must be educated about the dangers associated with those items
department that performs central service functions may go by other names at different facilities.
department dress code apply to:
detergents used in mechanical cleaners should be:
develops nationally recognized standards, recommended practices and guidelines for the perioperative setting
develops recommended standards, practices, and guidelines for care and processing of devices
disadvantages to a case cart distribution system:
disposable components should be removed at point of use
disposable components such as pads and tubing on patient care equipment should be:
disposable sharp items should be removed at point of use and placed in a BLANK container labeled biohazard
during handwashing, hands should be lathered for at least
during instrument manufacture the process of passivation helps protective chromium oxide layer on each instrument's surface
each year, approximately BLANK patients develop a healthcare-associated infection
failure to receive accreditation from the joint commission can result in the loss of medicare and medicaid payments
female reproductive organs
flash sterilization of implants is NOT recommended by flexible endoscopes that fail a leak test may continue to be used until the break/hole impacts the scope's function
floors in the central service department should be:
following OSHA regulations for wearing personal protective equipment in the central service decontamination area is optional
for safety purposes, central service technicians should consider all microorganisms in the decontamination area
furthers international cooperation in improving health conditions
hands should be finish rinsed in what position
having the sediment or solids stirred up to appear cloudy silicate-a mineral derived from silica which is from quartz, sand, opal, etc.
healthcare regulations and standards provide consistency of departmental activities by outlining
heart valves and pacemakers are examples of FDA BLANK medical devices
herpes simplex in a BLANK disease
horizontal work surfaces in the decontamination area should be cleaned and disinfected once per day
how frequently should a steam sterilizers door gasket be inspected and cleaned?
how long must alcohol remain in wet contact with an item to achieve a reasonable level of disinfection? if a sterilizer has successfully killed all bacterial spores in a biological test CORRECT ANSWERS it is called a negative test
if an equipment malfunction causes harm to a patient, it should be:
if grossly soiled instruments cannot be cleaned immediately, they should be kept BLANK
if soiled items are held in a user units before pick up for processing, they must be kept at the patients bedside until central service collect them
[Show More]