ARDMS Exam 69 Questions with Verified Answers
Tendonitis of the thumb - CORRECT ANSWER de Quervain's disease
- Gripping of transducer
What is trigger finger? - CORRECT ANSWER inflammation of tendon sheath in the
...
ARDMS Exam 69 Questions with Verified Answers
Tendonitis of the thumb - CORRECT ANSWER de Quervain's disease
- Gripping of transducer
What is trigger finger? - CORRECT ANSWER inflammation of tendon sheath in the finger due to repeated gripping of the transducer
What does the FDA do for ultrasound? - CORRECT ANSWER Regulates instruments according to application, output intensities, and TI/MI
What does the AIUM recommend for ultrasound? - CORRECT ANSWER Prudent use of US in clinical environment by minimizing exposure time and output power
What US mode has the highest intensity? - CORRECT ANSWER PW doppler
- PW > CW doppler
What is Temporal average? - CORRECT ANSWER Average intensity during both the transmitting and receiving times (PRP)
What is pulse average? - CORRECT ANSWER Average intensity over the entire duration of the pulse (PD)
Why is biological effects lower in unfocused transducers compared to focused transducers? - CORRECT ANSWER Unfocused has a larger beam area --> less focused energy
What is the maximum exposure seen with no biological effects in 1) unfocused and 2) focused - CORRECT ANSWER 1) Unfocused - 100 mW/cm2
2) Focused - 1W/cm2
What is stable cavitation? - CORRECT ANSWER microbubbles already present in the media expand and contract via pressure from the wave
What is transient cavitation and at what intensity - CORRECT ANSWER Bubbles expand and collapse violently
- Pulses with intensity greater than 3300W/cm2 (10MPa) can induce it
How does frequency relate to MI and TI? - CORRECT ANSWER MI: Lowers MI
TI: Raises TI
What is duty factor? - CORRECT ANSWER Fraction of time that pulse US is on
PD/PRP
What is fractional bandwidth? - CORRECT ANSWER Bandwidth/operation frequency
What is a half value layer? - CORRECT ANSWER thickness of tissue required to reduce intensity by 1/2
- Known as depth of penetration/half boundary layer, or penetration depth
how are harmonic frequencies produced? - CORRECT ANSWER Non-linear interaction as the beam goes through tissue
- Not produced on reflections
How does harmonic frequency affect our resolution 3 - CORRECT ANSWER - Improves spatial by decreasing AR
- Improves contrast resolution
- Improves lateral resolution by having a narrower beam (reduces side lobes)
How to calculate half value layer? - CORRECT ANSWER 6/frequency or 3/attenuation coefficient
How is apodization achieved? - CORRECT ANSWER Nonuniform excitation/driving of elements in an array
- Reduces grating lobes
What is the aperture? - CORRECT ANSWER Size of transducer elements
What does dynamic aperture do overall? - CORRECT ANSWER Minimizes change in the width of the sound beam
What is the thickness of the piezeoelectric element related to? - CORRECT ANSWER Thickness is equal to half of the wavelength
How does the damping/backing layer help US? 2 - CORRECT ANSWER - Improves axial resolution
- Increases bandwidth
What is the thickness of the matching layer? - CORRECT ANSWER 1/4 wavelength thick
What does NFL depend on? - CORRECT ANSWER - Diameter of element
- Frequency
FL = D^2 x f / 6
= D^2/(4wavelength)
3 ways to increase contrast resolution - CORRECT ANSWER - Increase compression (DR)
- Increase frequency
- Decrease beam width
What is penetration depth limited by? 2 - CORRECT ANSWER - Propagation speed of medium
- Attenuation
What is directly related to FOV? - CORRECT ANSWER PRF
What is coded excitation? - CORRECT ANSWER Uses a series of pulses and gaps rather than a single driving pulse
Where does coded excitation occur? - CORRECT ANSWER In the pulser
How does coded excitation help? - CORRECT ANSWER Improves contrast/spatial/axial resolution
What two features is code excitation responsible for? - CORRECT ANSWER - Multifocal
- Harmonics
How does harmonics improve contrast? - CORRECT ANSWER Decreases noise - SNR
What are channels - CORRECT ANSWER - Individual signal paths for transmission and reception of the sound beam
- equal to number of elements
What does the master synchronizer do? - CORRECT ANSWER maintains and organizes the proper timing and interaction of the system's components
What does the pulser determine? - CORRECT ANSWER - PRF
- PRP
- Pulse amplitude
How to adjust amplification of the receiver? - CORRECT ANSWER Overall gain setting
What is the knee of the TGC curve? - CORRECT ANSWER Deepest region attenuation compensation can occur
How does rejection of the receiver improve the image? - CORRECT ANSWER Decreases acoustic noise
What is B color and what is its benefit - CORRECT ANSWER Presentation of different echo intensities in various colors
- Improves contrast resolution
What is a voxel? - CORRECT ANSWER 3D pixel
What is another name for PACS? - CORRECT ANSWER DIN/IMACS
What does the ACR do? - CORRECT ANSWER Develops standards for encoding patient file information and interpretation
What does DICOM do? - CORRECT ANSWER Standardizes protocols for communicating image systems
What does NEMA do? - CORRECT ANSWER Develops standards for encoding patient file information and intepretation
What is a speckle? - CORRECT ANSWER Echoes from the distribution of scatterers in ta tissue
How much resistance does arterioles account for? - CORRECT ANSWER 1/2 of total resistance in the systemic system
What is the Bernoulli effect? - CORRECT ANSWER Describes pressure and velocity through a cylinder/vessel
What is duplex imaging? - CORRECT ANSWER simultaneous anatomic imaging and doppler
What technique does CDI use to obtain doppler shift frequencies? - CORRECT ANSWER autocorrelation
How many pulses used for color information in CDI? - CORRECT ANSWER 3-32
How many doppler samples per scan line in CDI? - CORRECT ANSWER 100-400
3 ways to get rid of flash artifacts - CORRECT ANSWER 1. Increase PRF
2. Decrease color gain
3. Increase filtering of low flow velocities
What is operation testing? - CORRECT ANSWER Evaluates the US system as a diagnostic tool
- Includes entire ultrasound instrument
What components does acoustic output testing involve? - CORRECT ANSWER Only the pulser and transducer
What is an AIUM 100 test object? - CORRECT ANSWER A device without tissue properties that can measure system performance
What can't the AIUM 100 test object evaluate? 3 - CORRECT ANSWER 1. Gray scale
2. Compression
3. Penetration
What does a beam profiler do? - CORRECT ANSWER Plots 3D reflection amplitudes received by the transducer
How does stiffness affect the speed of sound? - CORRECT ANSWER Increased stiffness = increased c
What does acoustic impedance depend on? - CORRECT ANSWER Density and speed of sound
Construction probes 3 - CORRECT ANSWER - linear
- convex
- annular
Operation probes 3 - CORRECT ANSWER - sequenced
- phased
- vector
How does color threshold decrease noise? - CORRECT ANSWER Suppresses low echoes
What causes noise in doppler? - CORRECT ANSWER - clutter due to high amplitude of doppler frequency
What is a packet? - CORRECT ANSWER Multiple sample gates position in CDI
How to get rid of mirror effect in doppler? 2 - CORRECT ANSWER - Turn down doppler gain
- Changing angle
What causes noise/clutter? - CORRECT ANSWER High amplitudes
What is the delay portion of the TGC curve? - CORRECT ANSWER Where compensation begins to occur
What causes diastolic flow reversal? - CORRECT ANSWER High R distally