HVAC 230 Exam Review - Questions with Verified Answers What is the maximum distance from the appliance to a gas shutoff? 6' Where do you leave the installation and operation manual? on premise The venting charts in NFP
...
HVAC 230 Exam Review - Questions with Verified Answers What is the maximum distance from the appliance to a gas shutoff? 6' Where do you leave the installation and operation manual? on premise The venting charts in NFPA54 use what winter design temperature -10 to 4˚F What is the minimum pipe size of a condensate line? ¾" How far from roof edge shall appliance be installed? 6' Can CSST be connected to movable appliances? No Where do you find a drip? Where there is a possibility of wet gas How do we protect appliances in a residential garage? Approved barrier or located so they are not subject to damage What is the minimum free area for a single permanent opening when used to provide combustion air? 1in²/3000BTU/hr. Can you combine a solid and a liquid fuel burning appliance into the same chimney flue? No Where would you find the clearances for single wall pipe to a combustible material? Table 12.8.4.4 in NFPA 54 Where is a shut off located regarding an appliance connector? Upstream What type of appliance connector would you use with commercial cooking appliances that are moved for cleaning purposes? Connectors shall be listed in accordance with ANSI Z21.69/CSA 6.16, Connectors for Movable Gas Appliances What code would we follow to install an appliance in a repair garage? NFPA 30A Do you need a permit when installing a gas appliance? Yes Do you need a permit when replacing a minor part in a gas appliance? No Can you install a floor register in a bathroom in commercial buildings? No What is the maximum length of a dryer exhaust vent? Found in Manufacturers I&O What is the minimum clearance in front of all appliances? 30" What are we required to provide for an appliance that requires controlled chimney draft A listed double-acting barometric draft regulator What are the categories for negative draft appliances? 1 and 2 Do we need additional provisions for direct vent appliances? No Define make-up air Air needed to replace exhausted air Can we have return ducts terminate in the room with the furnace if the supply ducts terminate outside of the room? No What do we have to do before adding a new appliance to existing gas piping? Ensure it has adequate capacity Can we use manually operated dampers No Can you install a low sidewall register in the laundry room? Yes Are outdoor setback controls required on all boilers? Yes Are you required to insulate hot water piping? Yes if it falls under one of the conditions described in R403.5.3 IECC What does the code require for flexible transition duct used on a dryer exhaust duct system? Listed and labeled in accordance with ANSI/UL 2158A Can you install a flexible air duct directly to a furnace? No What is the ratio of air volume to BTU ratio if using room combustion air? 50 Cubic feet/1000BTU's What are the climate zones in NH? 5A and 6A How close to the ground can a floor furnace be installed 6" How far from combustibles must Type B gas vent be As listed What is the minimum distance from an inoperable window to an exit terminal? No minimum What is the minimum free air for a two permanent opening if it is horizontally ducted to the outdoors for combustion air? 1 in²/2000BTU/hr. What is the maximum length of a flexible air connector? 14' Side wall vent pipes should be located how far above a walkway 7' What table would you reference when sizing category 1 venting systems for multiple appliances that are vented to an interior masonry chimney with single wall pipe? 13.2(d) What is the clearance above a food service appliance? 4' What table would you reference when sizing category 1 venting systems for a single appliance that is vented into an exterior chimney with single wall pipe? Not allowed What chapter in NFPA 54 is used for vent sizing? Chapter 13 What shall each duct supply branch or register have? Volume damper If a burner is not listed as FVIR it must be installed how far above a floor in a residential garage 18"
[Show More]