Home Inspection Test 1 Questions and
Answers Already Graded A
The home inspector's job does not include: ✔✔providing an opinion on value
A typical home inspection: ✔✔takes two to three hours
A home inspection usually
...
Home Inspection Test 1 Questions and
Answers Already Graded A
The home inspector's job does not include: ✔✔providing an opinion on value
A typical home inspection: ✔✔takes two to three hours
A home inspection usually includes: ✔✔electrical, plumbing and insulation
Which of these is not a real inspection association? ✔✔Professional Association of Degreed Home
Inspectors
Which statement is false? ✔✔home inspectors are building code inspectors
Which of these is included in a typical home inspection? ✔✔carport
The home inspector's job is finished: ✔✔after the report is delivered
Most inspectors provide a report: ✔✔within 24 to 48 hours
Inspection reports do not usually include: ✔✔a plat of survey
Standards of Practice ✔✔allow the client to know what to expect
Which of the following is a real company legal structure? ✔✔limited liability company (LLC)
A sole proprietor: ✔✔has no separation of liability if a claim is filed against youA typical general liability insurance policy provides: ✔✔$1 to 2 million in coverage
Which of these additional services is licensed in most (or all) states? ✔✔termites
The pre-inspection agreement (inspection contract): ✔✔should be signed by the client before the
inspection begins
Things you need to market your business: ✔✔business cards, brochures, email and a decent
website
To promote your business, you should spend: ✔✔3-7% of your gross fees
You should consider doing a mailing to all past clients: ✔✔a couple of times a year
Which of these marketing methods is not effective for home inspectors? ✔✔yellow pages ads
Which of the following is not a common method of establishing an inspection fee? ✔✔overall
condition of the house
Licensing curriculums teach: ✔✔technical competency
Home inspectors offer expert opinions that are: ✔✔not legally binding
The oldest and most recognized Standards of Practice are from: ✔✔ASHI
The ASHI definition of "installed": ✔✔Attached such that removal requires tools
The ASHI Standards of Practice are applicable to buildings: ✔✔with four or fewer dwelling units
and their garages or carportsWhich of the following tools is not required to meet the Standards of Practice? ✔✔a gas leak
detector
Every good home inspector is a: ✔✔good communicator
The inspection order as taught in this course: ✔✔top down, outside-in
Never start an oven or dishwasher: ✔✔without checking the interior first
If any rooms or areas are blocked by stored items: ✔✔be sure to note this on the report as
"restricted view"
Dormers are: ✔✔"bump outs" in the roof to gain space
Traditional underlayment has been: ✔✔15 or 30 pound felt
A cricket is required on the high side of any chimney wider than: ✔✔30 inches
The top edge of counter flashing is either covered by siding or inserted into: ✔✔reglets
Which of the following is not a valley type? ✔✔stacked
The most common roofing material in North America is: ✔✔asphalt
A valley style unique to slate: ✔✔rounded
Three typical top applications on a flat roof: ✔✔gravel, flood coat, seal coatA flat roof is less than: ✔✔2:12 slope
If you see broken chimney tiles: ✔✔recommend a masonry contractor
With "dead end" valleys you should: ✔✔check the attic or ceilings below for leaks or stains
Failed rubber at plumbing vents: ✔✔is common
Turbine vents: ✔✔are often rusted and "locked up"
Black streaks on cedar shingles from galvanized nails: ✔✔are only a cosmetic issue
Short chimneys: ✔✔can cause down-drafting into the house
Chimneys have an exterior: ✔✔chase
The top of the chimney is known as the: ✔✔crown
All chimneys must be at least 3 feet above the roof and: ✔✔2 feet taller than anything within 10
feet
All gas vents must be a minimum of 12 inches above a roof and a minimum of: ✔✔2 feet taller
than anything within 8 feet
Downspouts should be extended away from the house: ✔✔a minimum of 5 feet
As per the ASHI Standards of Practice, you are not required to inspect: ✔✔fences
A sign of a problematic crack may be: ✔✔widening from the point of originThe dominant siding material in the United States is: ✔✔vinyl
"Seamless" vinyl siding: ✔✔is really 40 feet long
The EPA Renovation, Repair and Painting Rule applies to homes built before: ✔✔1978
Engineered wood siding is also known as: ✔✔composite wood
T1-11 is a style of: ✔✔plywood siding
Older fiber cement siding (pre-1970's) contains: ✔✔asbestos
Traditional stucco siding: ✔✔is applied in two or three coats
EIFS (Exterior Insulation and Finish System): ✔✔dents and cracks easily, allowing moisture
infiltration
White deposits on concrete and masonry, caused by chronic moisture, are known as:
✔✔efflorescence
Lintel bearing on masonry should be: ✔✔6 inches
Thin bricks are also sometimes called: ✔✔faux brick
Manufactured stone: ✔✔is made with concrete, real stone chips and colorants
A flashing type commonly used with siding to protect a trim board: ✔✔"Z" flashingKeyed deadbolts on exterior doors: ✔✔are a safety hazard in an emergency
Perimeter railings on decks should be: ✔✔at least 36 inches high
Maximum opening through any part of a perimeter railing is: ✔✔4 inches
All vegetation: ✔✔should be trimmed at least 12 inches away from the house
You are not required to inspect: ✔✔shutters
Trusses: ✔✔cannot be field modified unless directed by a structural engineer
The maximum notch typically allowed in a solid wood joist is: ✔✔1/6 joist depth
The thickness of an I-joist web is: ✔✔3/8 inch
The top and bottom flanges of an I-joist: ✔✔can never be cut, notched or modified
The maximum notch typically allowed in a beam: ✔✔should never be cut or notched anywhere
A short column is known as a: ✔✔pier
"Checking" in old columns: ✔✔is common and is usually acceptable
Defects with engineered products such as trusses or I-joists should be referred to: ✔✔a licensed
structural engineer
Defects with dimensional lumber should be referred to: ✔✔a qualified framing contractor
(carpenter)Epoxy grouting: ✔✔stops seepage
Deck failures: ✔✔are fairly common
Deck ledger boards should always be: ✔✔bolted
Deck defects should always be referred to: ✔✔a qualified framing contractor (carpenter)
Wall cracking from seasonal changes is usually: ✔✔straight and vertical
What is not common for older homes to have? ✔✔I-joists
Cracking at wall-ceiling intersections in the center of the house may be from: ✔✔truss uplift
Floor heaving along an outer foundation wall is often a sign of: ✔✔foundation settlement
Maximum hole size in a dimensional joist is: ✔✔1/3 joist depth
What is not a common place to find rotted floor sheathing? ✔✔under bedrooms
What is not a common name for a method of reducing joist twisting and rotating? ✔✔spanning
Electric eye sensors for garage door openers should be: ✔✔maximum 4 inches from floor
Attached garages should have a _____ between the house and garage: ✔✔fire-wall
Which is not a typical roof sheathing material? ✔✔T1-11Painting attic framing indicates: ✔✔a past fire or mold remediation
The higher the R-value: ✔✔the better the insulation
Without a vapor barrier, attic ventilation should be: ✔✔one square foot of ventilation per 150
square feet of attic floor
Typical minimum ceiling height is: ✔✔7 feet
"Nail pops": ✔✔are common and can usually be pounded back in and patched
If a wall stain is dry: ✔✔it's not actively leaking today
Multiple cracked floor tiles may mean: ✔✔the floor has too much deflection
In bathrooms, check for soft floors: ✔✔by carefully stepping on them
Stair risers are typically: ✔✔7 to 8 inches tall
Stair treads are typically: ✔✔9 to 11 inches wide
In most areas, stair handrails are required with more than: ✔✔3 risers
Safety glass is required: ✔✔within 60 inches above a tub or shower floor
Maximum window sill height above a floor (current practice) should be: ✔✔44 inches
Which of these appliances are not usually checked by home inspectors? ✔✔portable microwaveIn a basement, if access is blocked by stored items: ✔✔you should report it and include a photo
Water piping at a crawl space vent in a cold weather climate: ✔✔is a freeze hazard
Stains and mold at basement corners are often caused by: ✔✔a lack of gutter downspout leaders
As per the Standards of Practice, you are not required to inspect: ✔✔clothes washing machine
connections
Copper pipe types: ✔✔K, L, M
PVC pipe is: ✔✔white
A pipe fitting which prevents galvanic corrosion: ✔✔dielectric union
The two types of cross connections: ✔✔direct and indirect
A common cross connection at a utility sink: ✔✔a hose connected to the faucet
Typical lifespan for horizontal cast iron pipe: ✔✔40 to 50 years
ABS pipe is: ✔✔black
Brass is often used for: ✔✔P-traps
An air admittance valves: ✔✔eliminate the need for vent piping from each fixture
Showers and bathtubs should have a trap below the floor and within: ✔✔24 inchesFunctional flow testing is: ✔✔running all fixtures in the same bathroom at once
For any faucet in any room: ✔✔hot should be to the left
The minimum distance from a wall to the centerline of a toilet is: ✔✔15 inches
Glass shower doors should be: ✔✔safety glass
Water heaters built after July 2003 are: ✔✔FVIR type
Single wall vent for gas/propane requires _______ clearance to combustibles: ✔✔6 inches
Double wall B-vent for gas/propane requires _______ clearance to combustibles: ✔✔1 inch
Vent connectors must rise: ✔✔a minimum of 1/4 inch per foot
Storage tank combustion water heaters typically last: ✔✔10 to 12 years
The TPR valve must be: ✔✔properly rated and properly piped
Popping noises in a combustion water heater indicate: ✔✔the tank is filled with sediment
A proper gas burner flame should be: ✔✔blue
If copper pipe is used for gas: ✔✔it should be labeled for gas
The gas piping material most commonly used in a home (currently) is: ✔✔CSSTAs per recommendations by both manufacturers and national model codes: ✔✔CSST gas piping
systems shall be bonded to the electrical service
CSST is: ✔✔yellow
Flexible appliance connectors: ✔✔cannot pass through any floor, wall or ceiling
Oil burners should have an emergency switch: ✔✔well away from the burner
A storm water sump pump can usually be connected to a: ✔✔storm sewer
Combustion heating equipment requires large amounts of: ✔✔air
Which is not a forced air furnace configuration? ✔✔vertical
Listed gas fired units use: ✔✔B-vent
Metal louvers are ______ net free area: ✔✔75%
Return air grilles must be a minimum of 10 feet from any combustion source OR: ✔✔separated
by a tight fitting door
Garage furnaces: ✔✔should be protected from vehicle impact
A blower interlock: ✔✔prevents operation if the blower compartment panel is missing
Uncoated brass appliance connectors: ✔✔are a safety
[Show More]