Home Inspection Questions and
Answers Rated A
Branch circuitconductorsarethe____________ ✔✔wires to the outlet
Voltage is equal to ✔✔amps X resistance
If a service entrance has a 200-amp supply, the minimum cable siz
...
Home Inspection Questions and
Answers Rated A
Branch circuitconductorsarethe____________ ✔✔wires to the outlet
Voltage is equal to ✔✔amps X resistance
If a service entrance has a 200-amp supply, the minimum cable size should be? ✔✔2/0 copper or
4/0 aluminum
The following item is safe to insert into an electrical panel: ✔✔Nothing
The main panel is also called the? ✔✔Electrical Panel
_____ are the units used to measure resistance. ✔✔Ohms
AWG means_____ and is a standardized wire gauge system. ✔✔American Wire Gauge
Branch circuit conductors are the ? ✔✔Wires to the outlets
A____-amp breaker should supply a minimum # 12 conductor. ✔✔20
The maximum breaker rating must ____the allowed ampacity of the conductor. ✔✔not exceed
____ is/are considered unsuitable to wear during an inspection. ✔✔Nylon Clothing
A live wire is sometimes called an? ✔✔Ungrounded ConductorFor a 14-gauge copper wire, the maximum over-current protection rating is ____ amps. ✔✔15
What would cause rafter spread? ✔✔Inadequate knee walls
Roof sheathing should be installed____ to the rafters. ✔✔Perpendicular
De-lamination of the roof sheathing may cause? ✔✔Depression between the rafters
The horizontal board enclosing the ends of the rafter projections ( or Tails) is normally referred to
as the ____board. ✔✔Fascia
The distance that should separate the siding from the roof's surface is? ✔✔1 to 2 inches
Small dimples or circular depressions on asphalt shingles are often caused by___? ✔✔Hailstones
Most Jurisdictions allow more than ___ layers of asphalt shingles. ✔✔two
T/F: Slate tile roofs should never be walked on? ✔✔True
T/F:Most concrete and clay tiles are installed the same way. ✔✔True
Fasteners made of_____ are recommended for tile roofs. ✔✔Copper or stainless steel
T/F: Wood Shingles should be installed over tap paper or similar underlayment, although this is
not always required if installed over skip sheathing. ✔✔True
Wood shakes and shingles should be used only on roofs with a slope of at least? ✔✔4:12Concrete and clay tile roofs with a slope of less than 4:12 require____ layers of underlayment.
✔✔Two
A wood shingle is ____-cut, whereas a shake is split by____? ✔✔Machine.....Hand
Asphalt shingles use either____or_____ as a base. ✔✔Cellulose....Fiberglass
T/F: it is not necessary to note previous shingle repair if the repair was preformed by a professional.
✔✔False
T/F: Clay tiles are easily distinguishable from concrete tiles. ✔✔False
The inspector should___ when reporting on an asbestos cement tile roof. ✔✔Not the roof material
The size of a standard roll roofing is ____ inches wide. ✔✔36
The layers that make up a built-up roof are called. ✔✔Plys
T/F: alligatoring of a roof covering is only a cosmetic issue. ✔✔False
When a flat roof has water stains, these are signs of previous. ✔✔Ponding
Metal roof tiles are typically made of___. ✔✔Steel
Crushed Stone or gravel ballast on a built-up rood___. ✔✔Protects the roof from sunlight
_____ is normally used for flashing. ✔✔Timber_____ flashing is the type of flashing that goes between the roof covering and the sheathing around
the roof's perimeter. ✔✔Drip Edge
A flashing along the peak of the roof is called the ✔✔Ridge
A closed valley means that the valley flashing___. ✔✔Cannot be seen
Metal valley flashing should be a minimum of ___ inches wide. ✔✔24
For most tile roofs, a standard step flashing cannot be used against a wall, so a _____ flashing
must be installed. ✔✔Pan
The bottom of . roof should have a ____ flashing where it meets a wall. ✔✔Kickout
T:F/ A common location for an apron flashing is at the front side or downslope side of a chimney.
✔✔Ture
An attic with an area of 600 square feet with ridge and soffit vents should have a total vent area of
___ square feet. ✔✔2
The____ effective venting system for most type of roofs is ridge and soffit vents. ✔✔Most
An attic space with only gable vents should have a vent area of 1 square foot per___ square foot
of floor area. ✔✔150
T/F: roof vents are required for roof vents with an unconditioned attic space. ✔✔True
Flat roofs normally have____ venting systems. ✔✔PassiveT/F: Ice dams are caused by poor venting and inadequate insulation. ✔✔True
A typical Chimney is a minimum of____ feet high. ✔✔3
If a roof ridge is closer than 10 feet to a chimney, the stack should be ___ feet higher. ✔✔2
The process of repairing missing mortar between brick joints is called__. ✔✔Re-pointing
The difference between a chimney cap and a rain cap is. ✔✔a chimney cap protects the structure,
and a rain cap protects the inside of the flue.
T/F: All chimneys should have a spark arrestor fitted. ✔✔False
A clearance gap of___ inches is required between a manufactured chimney and combustibles.
✔✔2
T/F: A rain cap or deflector is required on all manufactured chimneys. ✔✔True
The proper name for the connection between a manufactured chimney flue and the roof is called
a. ✔✔Thimble
T/F: Manufactured chimney systems are not required to maintain the same separation from
adjoining structures as traditional chimneys. ✔✔False
Should the inspector inspect all the windows? ✔✔No
Should the inspector describe the exterior covering> ✔✔Yes
Should the inspector inspect for safety glass. ✔✔NoWhat does PPE stand for. ✔✔Personal Protective Equipment
______ is the main concern when inspecting the exterior. ✔✔Water
A_____ is a classical architectural element consisting of the triangular space found above the
horizontal structure or columns. ✔✔Pediment
A___ usually refers to the horizontal decorative trim at the top of an exterior wall and below the
edge of a building, but it can be found over a door or window, too. ✔✔Cornice.
A ___ window has two operable sashes that move. ✔✔Double-hung
The lites in a window sash are divided horizontally and vertiaclly by narrow strips of wood or
metal called . ✔✔Muntins
____ are vertical boards that run the full height of a door and compose its right and left edges.
✔✔Stiles
_____ are the horizontal boards at the top, bottom and (optionally) in the middle of a door that join
the two stiles. ✔✔Rails
Window____ in poor condition may allow air drafts, rattling and water penetration. ✔✔Putty
T/F: Fogged windows should be replaced. ✔✔True
Regardless of the size of the house, at least one ___ door should be provided. ✔✔Egress
A sill at a window or door should be ____. ✔✔SlopedDoors can assist in preventing____and reducing_____. ✔✔Firse___ noise
Functional sills on doors are sloped to diverts water where? ✔✔Away from the door
Door weather-stripping is generally of three types, what are they? ✔✔Metal, Foam plastic or
Plastic stripping
What is the name of a pair of swinging doors often found in public bars? ✔✔Saloon Doors
The ______ is the exterior wall covering or cladding of a house, considered the house's "skin"
✔✔Siding
The cross connection of two oil storage tanks is permitted if the total aggregate capacity does not
exceed____ gallons. ✔✔660
A sediment trap should be installed ___ of the equipment's shut off valve and as close to the inlet
of the equipment/appliance as possible. ✔✔Downstream
Where two or more vent connectors enter a common gas vent, chimney flue, or single-wall metal
pipe, the ______ connector should enter at the highest level consistent with the available head
room or clearance to combustible material. ✔✔smaller
Gas vent pipes terminating above roof pitches up to 6/12 need to be ____ high. ✔✔only 1 foot.
The joint between different types of plastic made solvent cement will not be reliable because the
material composition of the joint will not____ ✔✔Be homogeneousThe square shape of a clean out____ the possibility of stripping the plug during removal.
✔✔minimizes
T/F/Other: It is permitted, in certain situations, to discharge untreated sewage or waste water on
the ground surface. ✔✔False: It is never permitted.
Small siding failures may result in : ✔✔disproportionately greater structural damage
Siding is installed on the outer surface of what? ✔✔The exterior wall envelope
Nails that hold siding materials in place can be referred to as: ✔✔fasteners
Porous materials in a siding system, such as brick _______ water and dry out ✔✔absord
Siding material is not considered ✔✔insulation
The siding should not be considered the only barrier to ___ ✔✔water intrusion
The joints in exterior siding may allow some water penetration, but an air gap and ____ behind the
siding limit any penetration ✔✔water resistant barrier
Apart from providing the external appearance for the house, the primary function of cladding is to
protect the structure from weather -- particularly, to shed ______ ✔✔rainwater
T/F:rocks or blocks at any point could support drainage piping inside a trench. ✔✔False
Particular drainage fittings have been designed with patterns providing____ resistance to flow.
✔✔The leastThe minimum slope of a horizontal drainpipe that is sized between 3 and 6 inches is _____per
foot. ✔✔1/8 inches
Drainage pipe clean outs should be installed not more than____ apart in horizontal drainage lines
measured from the upstream entrance of the clean out. ✔✔100 feet
T/F: A clean out is required for each and every change in direction of the sewer drainage pipe.
✔✔False
The discharge pipe on a sump pump should have a ____ isolated to prevent previously pumped
discharge from returning to the pump. ✔✔check valve
Storm water, rainwater or ground water should not be drained into a ____. ✔✔Sewer system
Ground surface of the lot should be graded so as to drain surface water away from foundation
walls. The grade should be dropped a minimum of ___ inches within the first 10 feet. ✔✔6
Hangers and strapping should be made of approved material that will not promote___ Action.
✔✔Galvanic
The maximum horizontal spacing for PVC drainage is____feet. ✔✔4
The maximum horizontal spacing for support cast iron pipe is____ feet. ✔✔5
Strandpipes, like that for a clothes washer, should have a minimum height above the trap of_____.
✔✔18 inches
A water seal of____ inches is standard for most traps. ✔✔2 inchesMany old tailpices and traps are made of soft brass with chrome or nickle-plating that are somtimes
so thin that a gentle touch will cause them to ____. ✔✔Break into pieces
Toilets___ have traps. ✔✔Never
The vent pipe that passes through a roof should end at least_____ inches abof the roof. ✔✔6
There should be at least_____ vent pipe(s) that extend(s) to the outdoor air for a dweling. ✔✔one
An air of vapor barrier is not required in SIP buildings because properly sealed SIPs create a codecompliant are barrier with a permeability rating of less than 1 perm ✔✔true
_______ is especially crucial in an SIP structure , this can be done with foam ✔✔sealings
The U.S. _________ office of drinking water controls the quality requirements for water to be
classified as potable. ✔✔EPA
There are_____ wells (more than 25 feet deep) and _____wells(25 feet or less.
✔✔Deep.....Shallow
A(n) ______is the most efficient and dependable method of preventing backflow. ✔✔Air Gap.
The minimum diameter of water service pipe is typically____. ✔✔3/4-inch
Type copper tubing is the____ and typically used for underground water services. ✔✔Thickest.
In order to get the most meaningful results, it is good practice to inspect the plumbing fixtures at
the____point in the house. ✔✔Highest.Dwellings built far above street-level may have___ water pressure and water flow because
pressure______ as water is pushed vertically. ✔✔Low.....Drops
T/F: Solvent-cementing between ABS and PVC pipe is prohibited. ✔✔True
Fuel-Fired water heaters may not obtain combustion air from_____. ✔✔Bathrooms or toilet
rooms.
A suitable access opening, passageway and work space are required when a water heater is
installed in a(n)_____. ✔✔Attic
[Show More]