CBSPD Exam Questions and Answers
Graded A
What should the sterilizer access area pressure be? ✔✔Negative w/10 air exchanges per hour
What two steps are involved in decontamination? ✔✔1. Manual and/or automated mechani
...
CBSPD Exam Questions and Answers
Graded A
What should the sterilizer access area pressure be? ✔✔Negative w/10 air exchanges per hour
What two steps are involved in decontamination? ✔✔1. Manual and/or automated mechanical
cleaning
2. application of a thermal or chemical disinfection process
Define Cleaning... ✔✔The removal of contamination from an item to the extent necessary for
further processing or for the intended use.
nosocomial infections are well documented and caused by... ✔✔poor or ineffective
decontamination of instruments
What are Employee hazards in the decontamination process? ✔✔Technicians work with a large
amount of 1) unidentified bioburden 2) wet enviornment 3) handling contaminated sharps 4) must
know procedures for proper handling, equipment, cleaning/sterilization agents
How do you properly clean a device? ✔✔follow the device manufacturer's written instructions
What is the starting point in sterilization? ✔✔Cleaning
Define decontamination ✔✔The process of cleaning surgical instruments, patient care devices,
and all involved surfaces in order to render areas and items safe for handling and/or further
processing
What are physical safety hazards? ✔✔-good body mechanics -correct body techniques and posture
for lifting, pushing, pulling, and reaching -should be alert and correct anything that is a potentialinjury -lifts to lift heavy supplies, available work material, adjustable chairs, padding on sharp
edges, correct height tables -proper clothing can prevent injury
What is the weakest point of an instrument? ✔✔Box lock and jaws
What does the ABC system stand for? ✔✔A: large dollar amount items not used frequently
B: moderately priced and used frequently
C: items w/ low dollar value
What is just in time distribution? ✔✔Items are distributed to department by vendor no need for
sterile storage or inventory control.
What are specialty/ procedure carts? ✔✔Carts placed in specific departments based on procedures
personalized to needs of departments easily accessible.
What is case cart distribution? ✔✔visually in specialty areas case carts are delivered to department
case cart is specialized to departments needs
What is the exchange cart distribution? ✔✔Two identical carts are made one is out in the
department and other stays in SPD
What is par level distribution? ✔✔There is fixed inventory and when items become low they are
replenished from the stockroom per department/specialty
What is demand distribution? ✔✔An instrument/cart must be ordered in order to get it
What are the most common distribution systems? ✔✔1) demand 2)par-level 3)Exchange 4)case
carts 5) Specialty 6) Just in time
What is the air pressure of the sterile storage area? ✔✔positive air flows outWhat is shelf life ✔✔period of time which a sterile item is considered safe to use
event related not time related
When are packs most vulnerable to contamination? ✔✔Immediately after sterilization
What is it when a sterilizer's ability is tested under worst case conditions? ✔✔Small load testing
What is it called when a sterilizer is tested for sterilization under actual use conditions? ✔✔Max
load testing
How often is a Bowie Dick test ran? ✔✔Daily for dynamic air removal sterilizers
How much space should be between packages and chamber wall? ✔✔one inch
How should paper-plastic pouches be placed in a sterilizer? ✔✔plastic to paper or paper to plastic
tilted on side
How should basins be placed in a sterilizer? ✔✔on tilted side same direction
What should be placed on the bottom of the rack in a mixed load? ✔✔metal instruments
basin
other metal items
What should be placed on the top shelf? ✔✔textile packs and paper/plastic pouches
Textile packs should be placed how in a sterilizer? ✔✔sides
Solid bottom trays should be loaded now? ✔✔tilted on sidesHow should mesh bottom containers be loaded into the sterilizer? ✔✔flat on rack
If packages are still moist when the sterilizer doors are open bacteria can do what? ✔✔wick
through the package
How does steam sterilization occur? ✔✔by condensation
What cases are proven to have prions? ✔✔1) neurosurgery
2) opthamology (eye)
When should a flash sterilizer be monitored? ✔✔Weekly with a biological and a class 5 or class 6
indicator
What can not be processed in an express cycle? ✔✔porous items
items with lumens
When should a flash sterilizer be used? ✔✔In an emergency; a one of a kind instrument is dropped
How are liquids sterilized? ✔✔only through gravity displacement liquid cycles
What occurs during the drying phase? ✔✔Dynamic Air Removal: Filtered air is drawn in achieve
drying
Gravity: Heat in chamber evaporates moisture
*Approx.: 30 min. for both
What occurs during the exhaust phase? ✔✔steam is exhausted from the chamber drain lineWhat occurs during he sterilization/exposure/"holding phase"? ✔✔exposure temperature is
maintained for the prescribed amount of time
What occurs during the conditioning phase of steam sterilizers? ✔✔Air is removed and steam is
injected
Where should the bowie dick test be placed in a steam sterilizer ✔✔drain line
Where is the sterilizers heat-sensing thermometer located? ✔✔Drain- line
What provides heat inside the chamber and prevents condensation in a steam sterilizer? ✔✔the
jacket
where is the dedicated steam supply made? ✔✔a boiler
Steam kills microorganisms by_______ the protein ✔✔denaturing (coagulation)
True/false
Removing as many microorganisms as possible before sterilization enhances the probability of
microbial kill ✔✔true
What is the air exchange in sterile storage ✔✔4 per hour
What is the suggested release temperature of packs? ✔✔70 to 80 degree farenheit
How far from the floor should medical devices be stored? ✔✔8-10 inches from the f