Fluid to be removed divided by the treatment time tells us Correct Answer: the ultrafiltration rate
The normal range of resting respirations in an adult is Correct Answer: 12-20 breaths per minute
hives,itching,t
...
Fluid to be removed divided by the treatment time tells us Correct Answer: the ultrafiltration rate
The normal range of resting respirations in an adult is Correct Answer: 12-20 breaths per minute
hives,itching,tightness of the chest and respiratory distress may be signs and symptoms of Correct Answer: Anaphylaxis (severe allergic reaction)
pain at the venous needle site, along with respiratory difficulty and chest pain could be an indicator of Correct Answer: sterilant infusion
A rapid pulse of 104 beats/minute would indicate that the patient has Correct Answer: tachycardia
A marker used to determine the middle molecule clearance of a dialyzer is Correct Answer: urea
The National standard, based on the KDOQI (Kidney Disease Outcomes Quality Initiative) guidelines, for the Urea Reduction Rate (URR) is a ratio greater than Correct Answer: 65%
What lab tests are used to monitor anemia in the ESRD patient? Correct Answer: Hemoglobin/Hematocrit
ESRD specific tests such as BUN, Creatinine, and URR are Correct Answer: indicators of the adequacy of the renal replacement therapy
The accuracy of lab results depends on adherence to proper lab draw technique. You must ensure that labs are drawn Correct Answer: At the right time, right site, and right order
Albumin is an important test that tells about the patient's_________________status. Correct Answer: nutritional
which of these technician activities contributes to data collection used to measure quality outcomes? Correct Answer: ensuring accurate documentation
Which of the following is the most accurate measure of dialysis adequacy? Correct Answer: Kt/V
Biohazardous waste includes any material exposed to Correct Answer: blood
A patient's laboratory results indicate that the predialysis BUN level was lower than the post dialysis BUN level. When interpreting these findings the technician should seek the answer to which of these questions Correct Answer: Was the predialysis sample drawn from the venous port?
[Show More]