CCHT WATER Exam 37 Questions with Verified Answers
CHLORINE TESTING - CORRECT ANSWER REVERSE OSMOSIS (RO) MACHINES RUNS 15 MINUTES BEFORE PERFORMING ANY TOTAL CHLORINE TESTING
100 ML - CORRECT ANSWER THE CORRECT
...
CCHT WATER Exam 37 Questions with Verified Answers
CHLORINE TESTING - CORRECT ANSWER REVERSE OSMOSIS (RO) MACHINES RUNS 15 MINUTES BEFORE PERFORMING ANY TOTAL CHLORINE TESTING
100 ML - CORRECT ANSWER THE CORRECT AMOUNT OF WATER TO COLLECT FOR TOTAL CHLORINE TESTING
RPC ultra low total chlorine strips - CORRECT ANSWER STRIPS USED FOR CHLORINE TESTING
HOW LONG ARE RPC STRIPS - CORRECT ANSWER IMMERSED IN SAMPLE WATER FOR 60 SECONDS
WHEN SHOULD CHLORINE BE TESTED - CORRECT ANSWER PRIOR TO TREATMENTS IN THE MORNING AND EVERY 3-4 HOURS WHILE PATIENTS ARE DIALYZING
RPC ULTRA -LOW TOTAL CHLORINE STRIPS TEST - CORRECT ANSWER CHLORINE IN THE WATER AFTER CARBON TANK AND POST RO
0.00 to 0.09 ppm - CORRECT ANSWER total chlorine levels that are patient safe AND DOCUMENT IN "TMS" OR PAPER LOG
FIRST SAMPLE - CORRECT ANSWER SHOULD BE TAKEN FROM POST CARBON TANK 1 (WORKER )
SECOND SAMPLE - CORRECT ANSWER POST RO
IF CHLORINE IS NOTED POST RO - CORRECT ANSWER DO NOT INITIATE ANY PATIENT TREATMENT, AND DOCUMENT PER FACILITY POLICY AND PROCEDURE
CHLORINE BREAKTHROUGH - CORRECT ANSWER OCCURS POST CARBON TANK 1 (WORKER), IMMEDIATE ADDITIONAL TESTING SHOULD TAKE PLACE AFTER CARBON TANK 2 (POLISHER)
CARBON TANK 2 (POLISHER) - CORRECT ANSWER IF TANK SHOWS RESULTS ABOVE THE ACTION LEVEL IMMEDIATELY STOP TREATMENTS
BYPASS - CORRECT ANSWER YOU WILL PUT PATIENTS IN THIS IF CARBON TANK 2 (POLISHER) TEST POSTIVE FOR CHLORINE , DOCUMENT TMS OR TCL- 2 LOG EVERY 2 HOURS
MEDICAL DIRECTOR - CORRECT ANSWER AFTER CHLORINE BREAKTHROUGH , WHO MUST APPROVE TO RESUME NORMAL OPERATION AND SIGN INTO TMS OR TCL -2 LOG
WHO TO NOTIFY IF CHLORINE BREAKTHROUGH - CORRECT ANSWER CLINICAL MANAGER, TECHNICAL SERVICES , MEDICAL DIRECTOR AND DIRECTOR OF OPERATIONS
WATER HARDNESS - CORRECT ANSWER WATER EXISTING THE WATER SOFTENR
PARTS PER MILLION (PPM) - CORRECT ANSWER HOW WATER HARDNESS IS MEASURED
20 PPM - CORRECT ANSWER ACCEPTABLE LIMITS FOR WATER HARDNESS POST SOFTNER
HOW OFTEN WATER SOFTNER TEST DONE - CORRECT ANSWER THERE ARE 2 WATER HARDNESS TEST DONE DAILY, UNDER NORMAL OPERATING CONDITIONS
HARDNES STRIPS TEST FOR - CORRECT ANSWER CALCIUM AND MAGNESIUM
SAMPLE CONTAINERS ARE - CORRECT ANSWER RINSED 3 TIMES BEFORE A SAMPLE IS COLLECTED FOR TESTING
CONDUCTIVITY METETR - CORRECT ANSWER PHOENIX OR MYRON METER L
PHOENIX METER/ MYRON METER L - CORRECT ANSWER MEASURES CONDUCTIVITY , PH AND TEMPERATURE
PHOENIX METER/ MYRON METER L - CORRECT ANSWER ARE TESTED DAILY BEFORE USE
RESIDUAL STRIPS - CORRECT ANSWER IS TO TEST FOR RESIDUAL BLEACH AND MUST BE DONE AFTER DISINFECTION PROCEDURES
BACTERIAL AND ENDOTOXIN TESTING PARAMETERS - CORRECT ANSWER SHOULD BE TAKEN MONTHLY
colony forming unit (CFU) - CORRECT ANSWER THE FREQUENCY OF ROUNTINE HOLDING TANK AND WATER DISTRIBUTION LOOP DISINFECTION IS MONTHLY
20 CFU/ML - CORRECT ANSWER ACTION LEVEL FOR BACTERIA IN PRODUCT WATER EXITING THE "RO" AND ACTION LEVEL FOR BACTERIA FOR WATER IN THE TANK, PIPING AND DISTRIBUTION LOOP
0.125 EU/ML - CORRECT ANSWER ACTION LEVEL FOR ENDOTOXIN IN PRODUCT WATER EXITING "RO"
.25 EU/ML - CORRECT ANSWER ACTION LEVEL FOR ENDOTOXIN FOR WATER IN THE TANK , PIPING AND DISTRIBUTION LOOP
CLINICAL AND TECHNICAL MANAGEMENT - CORRECT ANSWER MUST TAKE ACTION FOR ANY LAB REPORT WITH BACTERIA AND ENDOTOXINS EXCEEDING ACTION LEVELS
WATER PATHWAY - CORRECT ANSWER IN THE DIALYSIS FACILITY BEGINS WHERE THE CITY WATER ENTERS THE FACILITY
HOLDING TANK LEVEL ALARM - CORRECT ANSWER MUST BE ON AT ALL TIMES
77 DEGREES F - CORRECT ANSWER IS THE RECOMMENDED WATER TEMPERATURE FOR IDEAL "RO" OPERATION , WARMER WATER MAY DAMAGE THE "RO" MEMEBRANE
PIPING WITHIN THE WATER TREATMENT DISTRUBTION LOOP - CORRECT ANSWER CAN BE MADE OF PVC, STAINLESS STEEL, PEX, TEFLON
BICARB JUGS - CORRECT ANSWER A. DISINFECT WITH 1:100 BLEACH WATER AND THEN RINSED WITH "RO"WATER UNTIL NEGATIVE FOR BLEACH
B. DISINFECT WEEKLY
MIXING BICARBONATE FOR DIALYSIS - CORRECT ANSWER A. MIXED PER PROCEDURE AND POLICY
B. MIXING IS NOT TO EXCEED 10 MINUTES
C. MUST BE USED THE SAME DAY