Optometry > QUESTIONS & ANSWERS > NCLE Test Questions (All)
NCLE Test Questions Assessment of the quality of the peripheral curves (blends of a rigid contact lens) is achieved by the use of thea. profile analyzer b. shadow graph c. keratometer d. burton l ... ight - ✔✔a. profile analyzer Contact lens power should be specified ina. back vertex power b. sphero-cylinder power c. power in situ d. posterier apical radius - ✔✔a. back vertex power The slit-lamp illumination that gives an overall view of the cornea but limits detail isa. sclerotic scatter b. diffuse c. specular reflection d. oscilatory - ✔✔b. diffuse When a keratometric miers reflected off a soft contact lens are only clear when the wearer blinks, the lens fit is tooa. small b. large c. steep d. flat - ✔✔c. steep Transient keratometric mier distortion is usually due toa. pre-ocular tear film abnormalities b. prolonged rigid lens wear c. prolonged soft lens wear d. irregular corneal astigmatism - ✔✔a. pre-ocular tear film abnormalities Epithelial edema which manifests itself clinically as central corneal haze, is verified by the slit lamp using sclerotic scatter illumination. What specific technique does the examiner use to see this condition? a. the naked eye and an angle between the slit lamp beam and the eye of 90˚ b. the blue cobalt filter of the slit lamp and an angle of about 45˚ c. the green filter of the slit lamp with high magnification d. high magnification and an angle between the beam and scope of 180˚ - ✔✔a. the naked eye and an angle between the slit lamp beam and the eye of 90˚ With a rigid contact lens in place a flourescein pattern shows a narrow bend horizontally wih a concentration of flourescein inferiorly and superiorly under the lens. Which one of the following type of astigmatism is represented by this pattern? a. lenticular astigmatism b. residual astigmatism c. against the rule astigmatism d. with the rule astigmatism - ✔✔d. with the rule astigmatism Refractive Rx -3.00 -1.00 x 170 K's 42.00 @ 170/43.00 @ 80 Given the above Rx and K's he following diagnostic toric soft lens was used: B.C. 8.8 Power -3.00 -1.00 x 180 During dianostic evalutation, the above lens rotated 10 clockwise. The lens ordered should have an axis of: a. 10 b. 180 c. 170 d. 160 - ✔✔b. 180 Given the same circumstances from the above question, once the correctly ordered lens has been dispensed, the rotational marks should settle at _______. a. 6 o clock b. 10 clockwise rotation c. 10 counter clockwise rotation d. none of the above - ✔✔b. 10 clockwise rotation An instrument that allows simultaneous verification of lens diameter, optic zone width, and peripheral curve width is: a. measuring magnifier b. ophthalmometer c. profile analyzer d. radiuscope - ✔✔a. measuring magnifier (the book says d. radiuscope) The instrument used for magnification of the edge of a rigid CL is a _______. a. radiuscope b. shadowgraph c. profile analysis d. keratometer - ✔✔b. shadowgraph Mary is wearing in her right eye RGP lens with a base curve of 43.50 and a power of +2.75. The doctor refracts -0.75 sphere over this lens. If you wish to order her a new lens with a curve of 43.00, what will the new power be? a. +1.50 b. +2.00 c. +2.50 d. +3.00 - ✔✔c. +250 Which of the following could be considered in the fitting of a keratoconus patient 1. aspheric 2. McGuire 3. Soper 4. tangent streak a. 1 & 2 b. 2 & 3 c. 3 & 4 d. 1, 2 and 3 - ✔✔d. 1, 2 and 3 Two designs helpful in orienting high riding myopic lenses are: 1. flattening the B.C. relationship 2. myo-flang 3. hyper-flang 4. prism ballast a. 1 & 2 b. 1 & 3 c. 2 & 3 d. 3 & 4 - ✔✔d. 3 & 4 Age/related signs of presbyopia include: 1. tear film abnormalities 2. reduce lid elasticity 3. lens opacities 4. pupil constriction a. 1 only b. 1 & 3 c. 2 & 4 d. all of the above - ✔✔d. all of the above A good example of a bifocal contact lens which may rotate without vision imparement is: a. aspheric b. executive c. fused crescent d. tangent streak - ✔✔d. tangent streak Keratoconus and penetrating keratoplasty fittings are best accomplished by which of the following methods? a. nomogram b. Ks and Rx c. diagnostic fitting d. molded impression - ✔✔c. diagnostic fitting [Show More]
Last updated: 3 years ago
Preview 1 out of 25 pages
Buy this document to get the full access instantly
Instant Download Access after purchase
Buy NowInstant download
We Accept:
Can't find what you want? Try our AI powered Search
Connected school, study & course
About the document
Uploaded On
Jul 08, 2022
Number of pages
25
Written in
All
This document has been written for:
Uploaded
Jul 08, 2022
Downloads
0
Views
155
Scholarfriends.com Online Platform by Browsegrades Inc. 651N South Broad St, Middletown DE. United States.
We're available through e-mail, Twitter, Facebook, and live chat.
FAQ
Questions? Leave a message!
Copyright © Scholarfriends · High quality services·