Risk Management and Insurance > QUESTIONS & ANSWERS > 2022 IRC Exam Prediction (All)
2022 IRC Exam Prediction Storm drainage sump pumps shall be of a capacity and head appropriate to _______ use requirements. - ✔✔anticipated Electrical services within the scope of the IRC are l... imited to _____-volt, 0- to _____- ampere, single-phase systems. - ✔✔120/240 & 400 Boiler pressure-relief valve discharge shall be pipes to drains by gravity to within _____ inches of the floor or to an open receptor. - ✔✔18 Polyethylene tubing for hydronic piping systems shall be installed with _____ ______ joints. - ✔✔heat fusion The maximum amount of fuel oil stored above ground or inside a building shall be _____ gallons. - ✔✔660 (The supply tank shall be supported on rigid noncombustible supports to prevent settling or shifting) Vent piping on oil tanks shall be not smaller than _____-inch pipe. - ✔✔1 1/4 Oil tank vent piping shall terminate outside of building at a point not less than _____ feet, measured vertically or horizontally, from any building opening. - ✔✔2 Components of a solar thermal energy system that might be subject to pressure drops below atmospheric pressure during operations shall be protected by a _____-_____ _____. - ✔✔vacuum-relief valve The minimum unobstructed total area of the outside and return air ducts or openings to a forced air warm-air FURNACE shall not be less than _____ square inches for each 1000 Btu/h output rating. - ✔✔2 (This also applies to supply ducts.) Domestic clothes dryer transition ducts shall be metal and limited to a single length not to exceed _____ feet. - ✔✔8 (Transition ducts shall not be concealed within construction.) What size are fuel-gas-fired domestic clothes dryer ducts? - ✔✔4 inches The lowest portion of a gas floor furnace shall have not less than ______-inch clearance from grade level. - ✔✔6 (Except where the lower 6-inch portion of the floor furnace is sealed by the manufacturer to prevent entrance of water, the minimum clearance shall be reduced to not less than 2 inches.) Vent connectors for draft-hood-equipped appliances shall not be _____ than the draft hood outlet diameter. - ✔✔smaller A Type B-W gas vent shall terminate at least _____ feet in vertical height above the bottom of the wall furnace. - ✔✔12 A Type B or a Type L gas vent shall terminate at least _____ feet in vertical height above the highest connected APPLIANCE DRAFT HOOD or FLUE COLLAR. - ✔✔5 Gas APPLIANCE shutoff valves shall be located in the same room as the APPLIANCE and not further than _____ feet from the APPLIANCE. - ✔✔6 (Each appliance shall be provided with a shutoff valve separate from the appliance.) Fuel gas appliance connectors shall not exceed an overall length of _____ feet. - ✔✔6 Gas vents over 12 inches in size shall terminate not less than _____ feet above the highest point where they pass through the roof. - ✔✔2 (Amd at least 2 feet higher than any portion of a building within 10 feet) Underground fuel gas PIPING SYSTEMS shall be installed a minimum depth of _____ inches below grade. - ✔✔12 (Except that individual lines to outside lights, grills or other appliances shall be installed a minimum of 8 inches below grade, provided it is not subject to physical damage.) Shield plates, when required to cover the area of concealed gas piping, shall be a minimum _____ gage. - ✔✔No. 16 Where gas piping is concealed and run within _____ inches from the framing member face to which the membranes will be attached it shall be protected by shield plates. - ✔✔1 1/2 Fuel gas PIPING installed across roof surfaces shall be elevated not less than _____ inches above the roof surface. - ✔✔3 1/2 BTU is the abbreviation for _____ _____ _____, which is the quantity of heat required to raise the temperature of 1 pound of water 1°F. - ✔✔British Thermal Unit When doing a water test on DWV systems during rough-in plumbing, each section shall be filled with water to a point not less than _____ feet above the highest fitting in that section. - ✔✔5 (Water shall be held in the section under test for 15 minutes. The system shall prove leak free by visual inspection.) When doing an air test on DWV systems during rough-in plumbing, the portion under test shall be maintained at _____ psi for _____ minutes. - ✔✔5 & 15 Water service pipe shall be installed not less than _____ inches deep and not less than _____ inches below frost line. - ✔✔12 & 6 Trenching installed parallel to footings shall not extend below the _____-degree bearing plane of the bottom edge of a wall or footing. - ✔✔45 In plumbing systems, supports for 1-inch copper or copper allow tubing run horizontal shall not be spaced more than _____ feet apart. - ✔✔6 (Review and know how to use this table.) Fixture tail pieces shall not be less than _____ inches in diameter for sinks, dishwashers, laundry tubs and similar fixtures. - ✔✔1 1/2 (And not less than 1 1/4 inches in diameter for bidets, lavatories and similar fixtures. ) The center line of water closets or bidets shall not be set less than _____ inches from adjacent side walls or partitions. - ✔✔15 There shall be at least _____ inches clearance in front of the water closet, bidet or lavatory to any wall, fixture or door. - ✔✔21 Waste receptor standpipes shall extend a minimum of _____ inches and a maximum of _____ inches above the trap weir. - ✔✔18 & 42 (Access shall be provides to all standpipe traps and drains for rodding.) Shower compartments shall have at least _____ square inches of interior cross-secrional area. - ✔✔900 Lavatories shall have waste outlets not less than _____ inches in diameter. - ✔✔1 1/4 (A strainer, pop-up stoper, crossbar or other device shall be provided to restrict the clear opening of the waste outlet.) Bathtubs shall be equipped with waste outlets and overflow outlets connected to piping at least _____ inches in diameter. - ✔✔1 1/2 (The waste outlet shall be equipped with an approved stopper.) Sinks shall be provided with waste outlets not less than _____ inches in diameter. - ✔✔1 1/2 (A strainer, crossbar or other device shall be provided to restrict the clear opening of the waste outlet.) Each compartment of a laundry tub shall be provided with a waste outlet not less than _____ inches in diameter. - ✔✔1 1/2 (A strainer or crossbar to restrict the clear opening of the waste outlet.) Floor drains shall have waste outlets not less than _____ inches in diameter and a removable strainer. - ✔✔2 (Floor drains shall not be located under or have their access restricted by permanently installed appliances.) Bottom fed tank-type water heaters and bottom fed tanks connected to water heaters shall have a _____ _____ valve installed. - ✔✔vacuum_relief (In compliance with ANSI Z21.22) The maximum static pressure OF A WATER SERVICE shall be _____ psi. - ✔✔80 The minimum size water service pipe shall be _____ inch. - ✔✔3/4 A _____-_____ fire sprinkler system shall be seperate and independent from the water distribution system. - ✔✔stand alone (A multipurpose fire sprinkler system shall supply domestic water to both fire sprinklers and plumbing fixtures.) The fire sprinkler water supply shall provide the required design flow rate for _____ minutes for one-story dwellings less than _____ square feet in area. - ✔✔7 & 2000 Where chlorine is uses for disinfection in nonpotable water systems, the water shall contain not more than _____ ppm of chloramines or free chl [Show More]
Last updated: 2 years ago
Preview 1 out of 18 pages
Buy this document to get the full access instantly
Instant Download Access after purchase
Buy NowInstant download
We Accept:
Can't find what you want? Try our AI powered Search
Connected school, study & course
About the document
Uploaded On
Jul 08, 2022
Number of pages
18
Written in
This document has been written for:
Uploaded
Jul 08, 2022
Downloads
0
Views
98
In Scholarfriends, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.
We're available through e-mail, Twitter, Facebook, and live chat.
FAQ
Questions? Leave a message!
Copyright © Scholarfriends · High quality services·