Social Sciences > QUESTIONS & ANSWERS > TFM 12 Fire Alarm Technical Exam 2022 with complete solution (All)
TFM 12 Fire Alarm Technical Exam 2022 with complete solution Does a fire hood system and a kitchen need to be monitored by the fire alarm system? >>>Yes What does P.L.F.A stand for? >>>Power Limit ... ed Fire Alarm What does N.P.L.F.A stand for? >>>Non-Power Limited Fire Alarm What is the difference between P.F.L.A and N.P.F.L.A? >>>an N.P.L.F.A can operate at up to 600v, and the power output isn't limited a P.L.F.A has the voltage and power limited by a listed power source. What material must N.P.F.L.A circuit conductors be made from? >>>ONLY solid stranded copper is permitted. What does A.W.G stand for? >>>American Wire Gauge What size conductors are permitted? >>>Size 18 A.W.G and 16 A.W.G are permitted, provided they do not exceed certain capacities. What is used to protect transformers or other devices supplied from power-supply conductors? >>>An over-current device not rated over 20 amperes. When located within 7 feet of the floor, how shall cables be fastened? >>>Cables shall be fastened in an approved manner at intervals of not more than 18 inches. Single conductors shall not be smaller than ___ A.W.G? >>>18 Conductors of 28 A.W.G shall only be permitted in which circumstance? >>>Spliced with a connector listed as suitable for 26 to 24 A.W.G How shall P.F.L.A conductors NOT be installed? >>>P.F.L.A conductors shall not be strapped, taped, or attached to the exterior of any conduit or raceway. What is Plenum cable? >>>Cable that can be installed in ducts, plenums, or other spaces used for environmental air. What is a Riser cable? >>>Cable to be used in vertical wire runs in shafts between floors. Not to be used where Plenum cable is required. It is capable of preventing fire from rising from floor to floor.What is general purpose cable? >>>Cable for general purpose fire alarm use. Not to be used where plenum cable or riser cable is required. It is resistant to the spread of fire. Why 'type' shall plenum cable be? What substitutions are allowed? >>>Power Limited Fire Alarm Plenum (F.P.L.P) C.M.P can be substituted. Why 'type' shall riser cable be? What substitutions are allowed? >>>Power Limited Fire Alarm Riser (F.P.L.R) C.M.P, F.P.L.P [Show More]
Last updated: 3 years ago
Preview 1 out of 8 pages
Buy this document to get the full access instantly
Instant Download Access after purchase
Buy NowInstant download
We Accept:
Can't find what you want? Try our AI powered Search
Connected school, study & course
About the document
Uploaded On
Aug 31, 2022
Number of pages
8
Written in
All
This document has been written for:
Uploaded
Aug 31, 2022
Downloads
0
Views
310
Scholarfriends.com Online Platform by Browsegrades Inc. 651N South Broad St, Middletown DE. United States.
We're available through e-mail, Twitter, Facebook, and live chat.
FAQ
Questions? Leave a message!
Copyright © Scholarfriends · High quality services·