TFM 12 Fire Alarm Technical EXAM 90 QUESTIONS AND CORRECT ANSWERS 2025 GRADED A+.

Document Content and Description Below

TFM 12 Fire Alarm Technical EXAM 90 QUESTIONS AND CORRECT ANSWERS 2025 GRADED A+. TFM 12 Fire Alarm Technical 1. Does a fire hood system and a kitchen need to be monitored by the fire alarm system?: Y... es 2. What does P.L.F.A stand for?: Power Limited Fire Alarm 3. What does N.P.L.F.A stand for?: Non-Power Limited Fire Alarm 4. What is the difference between P.F.L.A and N.P.F.L.A?: an N.P.L.F.A can operate at up to 600v, and the power output isn't limited a P.L.F.A has the voltage and power limited by a listed power source. 5. What material must N.P.F.L.A circuit conductors be made from?: ONLY solid stranded copper is permitted. 6. What does A.W.G stand for?: American Wire Gauge 7. What size conductors are permitted?: Size 18 A.W.G and 16 A.W.G are permitted, provided they do not exceed certain capacities. 8. What is used to protect transformers or other devices supplied from power-supply conductors?: An over-current device not rated over 20 amperes. 9. When located within 7 feet of the floor, how shall cables be fastened?: Cables shall be fastened in an approved manner at intervals of not more than 18 inches. 10. Single conductors shall not be smaller than ___ A.W.G?: 18 11. Conductors of 28 A.W.G shall only be permitted in which circumstance?: - Spliced with a connector listed as suitable for 26 to 24 A.W.G 12. How shall P.F.L.A conductors NOT be installed?: P.F.L.A conductors shall not be strapped, taped, or attached to the exterior of any conduit or raceway. 13. What is Plenum cable?: Cable that can be installed in ducts, plenums, or other spaces used for environmental air. 14. What is a Riser cable?: Cable to be used in vertical wire runs in shafts between floors. Not to be used where Plenum cable is required. It is capable of preventing fire from rising from floor to floor. 15. What is general purpose cable?: Cable for general purpose fire alarm use. Not to be used where plenum cable or riser cable is required. [Show More]

Last updated: 6 months ago

Preview 3 out of 8 pages

Buy Now

Instant download

We Accept:

We Accept
loader

Loading document previews ...

Buy this document to get the full access instantly

Instant Download Access after purchase

Buy Now

Instant download

We Accept:

We Accept

Reviews( 0 )

$9.50

Buy Now

We Accept:

We Accept

Instant download

Can't find what you want? Try our AI powered Search

21
0

Document information


Connected school, study & course


About the document


Uploaded On

Jan 28, 2025

Number of pages

8

Written in

Seller


seller-icon
Reagan kaiya

Member since 9 months

1 Documents Sold

Additional information

This document has been written for:

Uploaded

Jan 28, 2025

Downloads

 0

Views

 21


$9.50
What is Scholarfriends

In Scholarfriends, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Scholarfriends · High quality services·