Physics > QUESTIONS & ANSWERS > PSI Test Practice Questions and Answers 2022 (All)
PSI Test Practice Questions and Answers 2022 The service disconnecting means may be installed in all of the following EXCEPT -Answer- the bathroom. What is the minimum size EMT conduit required ... for three 14 AWG, six 12 AWG, and three 8 AWG conductors? All wires are THHN solid wire. -Answer- 1 inch Overcurrent protection for feeders branch circuits supplying electric vehicle supply equipment shall be sized for continuous duty and shall have a rating of not less than what percentage of the maximum load of the electric vehicle supply equipment? -Answer- 125% A continuous load is a load where the maximum current is expected to continue for at least how long? -Answer- 3 hours The ampacity of the conductors from the generator terminals to the first distribution device(s) containing overcurrent protection shall not be less than what percentage of the nameplate current rating? -Answer- 115% ENT shall not be -Answer- threaded. A panelboard for a mobile home shall be rated not less than which of the following? -Answer- 50 amperes Disregarding exceptions, liquidtight flexible metal conduit shall be supported and secured at intervals not to exceed -Answer- 4 1/2 feet. What is the maximum weight of a luminaire that can be supported by the screw shell of a lampholder? -Answer- 6 pounds Disregarding exceptions, what is the minimum size copper-clad aluminum underground service conductor permitted? -Answer- 6 AwG The base of a 24-foot non-self-supporting ladder shall be placed approximately how far from the vertical structure upon which is leaning? -Answer- 6 feet Alternating-current systems of less than 50 volts shall be grounded where supplied by transformers, if the transformer supply system exceeds which of the following? -Answer- 150 volts to ground What is the maximum distance that the emergency controls for an attended self-service motor fuel dispensing facility shall be located from the dispensers? -Answer- 100 feet Where the negative polarity of a dc system does not serve as the connection point for the grounded conductor, which color finish can be used to identify the negative ungrounded conductor? -Answer- black One horsepower is equal to how many watts? -Answer- 746 The conductors, including splices and taps, shall not fill the wireway to more than what percentage of its area? -Answer- 75% outlet for a 12 AWG conductor with a listed outlet branch-circuit type arc-fault circuit interrupter installed at the first outlet What is the maximum permitted length of the branch-circuit wiring from the branch-circuit overcurrent device to the first box? -Answer- 70 feet Which type of surge protection device is permanently connected and intended for installation between the secondary of the service transformer and the line side of the service disconnect overcurrent device? -Answer- Type 1 What is the power of a 4-ohm resistive load connected to a 120-volt power supply? -Answer- 120v/4ohm=3OA 30X120V= 3600w Approximately how many kilowatts are used by a three-phase, 480- voit ac motor that draws a current of 52 amperes and has a power factor rating of 88 % -Answer- 480v x 52a x 1.735= 43180W x .88= 38000w What is the greatest root-mean-square (effective) difference of potential between any two conductors of a circuit defined as? -Answer- voltage A resistor has the following colored bands (in order): orange, red, brown, silver. What is the resistor value? -Answer- 320 Ohms (10% tolerance) What is the formula for calculating power (watts)? -Answer- R x I 2 One horsepower is equal to how many watts? -Answer- 746 A continuous load is a load where the maximum current is expected to continue for at least how long? -Answer- 3 hours For other than a totally enclosed switchboard or switchgear, what is the minimum amount of space that shall be provided between the top of the unshielded switchboard or switchgear and any combustible ceiling? -Answer- 36" What is the required width of the working space in front of electrical equipment with a 22-inch width? -Answer- 30 inches What is the minimum fire rating for electrical vaults housing electrical equipment over 600 volts, nominal? -Answer- 3 hours What is the maximum voltage drop for any branch circuit, separately derived system, operating at 120 volts line-to-line and 60 volts to ground, serving sensitive electronic equipment? -Answer- 1.5 % Service conductors installed as open conductors or multiconductor cable without an overall outer jacket shall have a minimum clearance of how many feet from porches and balconies? -Answer- 3 feet Where a feeder supplies continuous loads or any combination of continuous and noncontinuous loads, the minimum feeder conductor size shall have an allowable ampacity not less than the noncontinuous load plus what percentage of the continuous load? -Answer- 125% What is the recommended maximum total voltage drop on both feeders and branch circuits to the farthest outlet? -Answer- 5 [Show More]
Last updated: 3 years ago
Preview 1 out of 16 pages
Buy this document to get the full access instantly
Instant Download Access after purchase
Buy NowInstant download
We Accept:
Can't find what you want? Try our AI powered Search
Connected school, study & course
About the document
Uploaded On
Sep 07, 2022
Number of pages
16
Written in
All
This document has been written for:
Uploaded
Sep 07, 2022
Downloads
0
Views
103
Scholarfriends.com Online Platform by Browsegrades Inc. 651N South Broad St, Middletown DE. United States.
We're available through e-mail, Twitter, and live chat.
FAQ
Questions? Leave a message!
Copyright © Scholarfriends · High quality services·