Engineering > QUESTIONS & ANSWERS > Home Inspection Exam Prep Questions and Answers Graded A+ (All)

Home Inspection Exam Prep Questions and Answers Graded A+

Document Content and Description Below

Home Inspection Exam Prep Questions and Answers Graded A+ Ceiling joist when installed parallel to roof rafters, to prevent rafter spread, should be overlapped... - 3 inches - 4 inches - 5 inches... - 6 inches ✔✔3 inches What is the primary purpose of the control joints placed in concrete driveways?- To prevent cracking. - To drain the surface. - To reduce random cracking. - To enhance appearance. ✔✔To reduce random cracking Which of the following is an indication that a masonry wall is veneer and NOT structural? - No bond courses are seen. - The lintels are made of steel - The windows are inset 6" from the wall face. - There are no arches in the wall. ✔✔No bond courses are seen. Which roof covering is most appropriate for a roof with a slope of 1 1/2:12 above a single-family house? Assume standard installation of any required underlayment. - Metal shingles. - Wood shakes. - Modified bitumen. - Slate shingles. ✔✔Modified bitumen Historically, spaced or skip sheathing has been used for roof decking because it... - is economical and strong - provides a safe walking platform - allows for drying of roof material - retards attic ventilation ✔✔Allows for drying of roof material. What is the bare minimum for inspecting a roof? - Walking on the roof. - Viewing the roof from ladder at one location. - Viewing the roof from the ground. - Viewing the roof from the a ladder at multiple locations. ✔✔Viewing the roof from the ground. The water heater pressure relief valve discharge pipe MUST be: - A 3/4 inch pipe - Made of rigid pipe - Threaded at the bottom - As least the normal size of the relief valve outlet ✔✔As least the nominal size of the relief value outlet. Permeability is the property of a material that allows the passage of: - Water vapor. - Heat energy. - Liquid Water. - Infrared radiation. ✔✔Water vapor Which is the best example of the heat flow by conduction? - Heat flowing from the water inside to the body of a radiator. - Heat flowing from a forced-air supply register. - Heat flowing from a steam boiler inside pipes. - Heat flowing from a floor furnace. ✔✔Heat flowing from the water inside to the body of the radiator. Is bonding jumper needed for a gas hot water tank? - Yes, To eliminate stray voltage that could electrify the water in the tank. - Yes, Bonding jumpers ensure a continuous ground path even when the water heater is removed. - No, it is not required since the house is effectively bonded through the grounding electrode - Yes, the bonding jumper is installed strictly for lightening protection. ✔✔Yes, Bonding jumpers ensure a continuous ground path even when the water heater is removed. In new construction, which of the following items would NOT be considered an electrical system defect? - A #12 cooper wire is connected to a 15 amp breaker. - A #14 cooper wire is connected to a 20 amp breaker. - An incandescent light fixture next to a closet shelf. - Open knockouts are in an electrical panel. ✔✔A #12 copper wire is connected to a 15 amp breaker. A subpanel is a detached building has melted insulation on a neutral conductor. What is the most likely cause of this condition? - The neutral conductor is loose at the terminal bar. - The circuit breaker is defective. - There is no grounding electrode. - The circuit breaker ampacity is too large for the wire. ✔✔The neutral conductor is loose at the terminal bar. Capillary tubes are near to and attached to the... - evaporator coil - heat exchanger - condenser coil - compressor discharge ✔✔evaporator coil. A collar tie is found in: - the attic near the top plate - the basement between floor joists - a wall at the intersection of two walls - the upper third of the rafter length ✔✔the upper third of the rafter length During your inspection you see small white insects. What do you say to your clients? - Do not say anything. - There are termites in this property. - There is damage to the structure due to an insect infestation. - Suggest obtaining the services of a pest control operator. ✔✔Suggest obtaining the services of a pest control operator. Deck ledger boards with floor joists 16'6'', should be securely attached directly to the house by - Properly sized lag bolts every 16 inches. - 16d galvanized nails placed every 16 inches. - Properly sized joist hangers for the house. - Properly sized lag bolts into the foundation ledge. ✔✔properly sized lag bolts every 16 inches Roof truss uplift can cause cracks to form - above exterior window and doors. - at interior wall/ceiling intersections. - in bottom chords of roof trusses. - in top chords of roof trusses. ✔✔at interior wall/ceiling intersections. The framing method that uses studs continuously from the sill to the roof is called: - Post-and-beam construction. - Balloon framing. - Platform framing. - California framing. ✔✔Balloon framing. A scupper would most likely be located in: - a parapet wall. - a floor drain. - an oil furnace vent. - a K-type gutter. ✔✔A parapet wall Generally, which type of the item is NOT included in a home inspection? - Unsafe - Defective - Not present - Cosmetic ✔✔Cosmetic The primary function of a skimmer is to provide - a way for water to return to the pump. - a place to put chlorine tablets. - a means to remove floating debris from the water. - a secondary method of filtering the water. ✔✔a means to remove floating debris from the water. Polybutylene (PB) water supply tubing is seen in the house. You should report that it: - May require expensive replacement. - Is illegal to use this kind of pipe. - Should only have been used for waste pipe. - Is not a problem. PVC pipe is a problem. ✔✔May require expensive replacement. The term "wet vent" refers to a: - Vent that traps water and therefore stays wet. - Vent located above the roof line and exposed to rain. - Vent that runs outside an exterior wall. - Waste line that also functions as a vent. ✔✔Waste line that also functions as a vent. Smelling sewer gas near a bathroom sink indicates that the drain trap is: - Clogged - Undersized - Flooded - Dried out ✔✔Dried out Water is dripping from the cold water pipes above a gas water heater. This might be caused by: - Exhaust spillage. - Short cycling. - A cold start. - Overfiring. ✔✔Exhaust spillage Where is an S-Trap most likely to be located? [Show More]

Last updated: 2 years ago

Preview 1 out of 51 pages

Buy Now

Instant download

We Accept:

We Accept
document-preview

Buy this document to get the full access instantly

Instant Download Access after purchase

Buy Now

Instant download

We Accept:

We Accept

Reviews( 0 )

$10.50

Buy Now

We Accept:

We Accept

Instant download

Can't find what you want? Try our AI powered Search

146
0

Document information


Connected school, study & course


About the document


Uploaded On

Sep 09, 2022

Number of pages

51

Written in

Seller


seller-icon
Nutmegs

Member since 4 years

620 Documents Sold

Reviews Received
77
14
8
2
21
Additional information

This document has been written for:

Uploaded

Sep 09, 2022

Downloads

 0

Views

 146

Document Keyword Tags


$10.50
What is Scholarfriends

In Scholarfriends, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Scholarfriends · High quality services·