Branch circuitconductorsarethe____________ ✔✔wires to the outlet
Voltage is equal to ✔✔amps X resistance
If a service entrance has a 200-amp supply, the minimum cable siz
...
Home Inspection Questions and
Answers Rated A
Branch circuitconductorsarethe____________ ✔✔wires to the outlet
Voltage is equal to ✔✔amps X resistance
If a service entrance has a 200-amp supply, the minimum cable size should be? ✔✔2/0 copper or
4/0 aluminum
The following item is safe to insert into an electrical panel: ✔✔Nothing
The main panel is also called the? ✔✔Electrical Panel
_____ are the units used to measure resistance. ✔✔Ohms
AWG means_____ and is a standardized wire gauge system. ✔✔American Wire Gauge
Branch circuit conductors are the ? ✔✔Wires to the outlets
A____-amp breaker should supply a minimum # 12 conductor. ✔✔20
The maximum breaker rating must ____the allowed ampacity of the conductor. ✔✔not exceed
____ is/are considered unsuitable to wear during an inspection. ✔✔Nylon Clothing
A live wire is sometimes called an? ✔✔Ungrounded Conductor
For a 14-gauge copper wire, the maximum over-current protection rating is ____ amps. ✔✔15
What would cause rafter spread? ✔✔Inadequate knee walls
Roof sheathing should be installed____ to the rafters. ✔✔Perpendicular
De-lamination of the roof sheathing may cause? ✔✔Depression between the rafters
The horizontal board enclosing the ends of the rafter projections ( or Tails) is normally referred to
as the ____board. ✔✔Fascia
The distance that should separate the siding from the roof's surface is? ✔✔1 to 2 inches
Small dimples or circular depressions on asphalt shingles are often caused by___? ✔✔Hailstones
Most Jurisdictions allow more than ___ layers of asphalt shingles. ✔✔two
T/F: Slate tile roofs should never be walked on? ✔✔True
T/F:Most concrete and clay tiles are installed the same way. ✔✔True
Fasteners made of_____ are recommended for tile roofs. ✔✔Copper or stainless steel
T/F: Wood Shingles should be installed over tap paper or similar underlayment, although this is
not always required if installed over skip sheathing. ✔✔True
Wood shakes and shingles should be used only on roofs with a slope of at least? ✔✔4:12
Concrete and clay tile roofs with a slope of less than 4:12 require____ layers of underlayment.
✔✔Two
A wood shingle is ____-cut, whereas a shake is split by____? ✔✔Machine.....Hand
Asphalt shingles use either____or_____ as a base. ✔✔Cellulose....Fiberglass
T/F: it is not necessary to note previous shingle repair if the repair was preformed by a professional.
✔✔False
T/F: Clay tiles are easily distinguishable from concrete tiles. ✔✔False
The inspector should___ when reporting on an asbestos cement tile roof. ✔✔Not the roof material
The size of a standard roll roofing is ____ inches wide. ✔✔36
The layers that make up a built-up roof are called. ✔✔Plys
T/F: alligatoring of a roof covering is only a cosmetic issue. ✔✔False
When a flat roof has water stains, these are signs of previous. ✔✔Ponding
Metal roof tiles are typically made of___. ✔✔Steel
Crushed Stone or gravel ballast on a built-up rood___. ✔✔Protects the roof from sunlight
_____ is normally used for flashing. ✔✔Timber
_____ flashing is the type of flashing that goes between the roof covering and the sheathing around
the roof's perimeter. ✔✔Drip Edge
A flashing along the peak of the roof is called the ✔✔Ridge
A closed valley means that the valley flashing___. ✔✔Cannot be seen
Metal valley flashing should be a minimum of ___ inches wide. ✔✔24
For most tile roofs, a standard step flashing cannot be used against a wall, so a _____ flashing
must be installed. ✔✔Pan
The bottom of . roof should have a ____ flashing where it meets a wall. ✔✔Kickout
T:F/ A common location for an apron flashing is at the front side or downslope side of a chimney.
✔✔Ture
An attic with an area of 600 square feet with ridge and soffit vents should have a total vent area of
___ square feet. ✔✔2
The____ effective venting system for mos
[Show More]