Home Inspection Exam Prep Questions
and Answers Graded A+
Ceiling joist when installed parallel to roof rafters, to prevent rafter spread, should be overlapped...
- 3 inches
- 4 inches
- 5 inches
- 6 inches ✔✔3 inc
...
Home Inspection Exam Prep Questions
and Answers Graded A+
Ceiling joist when installed parallel to roof rafters, to prevent rafter spread, should be overlapped...
- 3 inches
- 4 inches
- 5 inches
- 6 inches ✔✔3 inches
What is the primary purpose of the control joints placed in concrete driveways?- To prevent
cracking.
- To drain the surface.
- To reduce random cracking.
- To enhance appearance. ✔✔To reduce random cracking
Which of the following is an indication that a masonry wall is veneer and NOT structural?
- No bond courses are seen.
- The lintels are made of steel
- The windows are inset 6" from the wall face.
- There are no arches in the wall. ✔✔No bond courses are seen.
Which roof covering is most appropriate for a roof with a slope of 1 1/2:12 above a single-family
house? Assume standard installation of any required underlayment.
- Metal shingles.
- Wood shakes.
- Modified bitumen.
- Slate shingles. ✔✔Modified bitumen
Historically, spaced or skip sheathing has been used for roof decking because it...- is economical and strong
- provides a safe walking platform
- allows for drying of roof material
- retards attic ventilation ✔✔Allows for drying of roof material.
What is the bare minimum for inspecting a roof?
- Walking on the roof.
- Viewing the roof from ladder at one location.
- Viewing the roof from the ground.
- Viewing the roof from the a ladder at multiple locations. ✔✔Viewing the roof from the ground.
The water heater pressure relief valve discharge pipe MUST be:
- A 3/4 inch pipe
- Made of rigid pipe
- Threaded at the bottom
- As least the normal size of the relief valve outlet ✔✔As least the nominal size of the relief value
outlet.
Permeability is the property of a material that allows the passage of:
- Water vapor.
- Heat energy.
- Liquid Water.
- Infrared radiation. ✔✔Water vapor
Which is the best example of the heat flow by conduction?
- Heat flowing from the water inside to the body of a radiator.
- Heat flowing from a forced-air supply register.
- Heat flowing from a steam boiler inside pipes.
- Heat flowing from a floor furnace. ✔✔Heat flowing from the water inside to the body of the
radiator.Is bonding jumper needed for a gas hot water tank?
- Yes, To eliminate stray voltage that could electrify the water in the tank.
- Yes, Bonding jumpers ensure a continuous ground path even when the water heater is removed.
- No, it is not required since the house is effectively bonded through the grounding electrode
- Yes, the bonding jumper is installed strictly for lightening protection. ✔✔Yes, Bonding jumpers
ensure a continuous ground path even when the water heater is removed.
In new construction, which of the following items would NOT be considered an electrical system
defect?
- A #12 cooper wire is connected to a 15 amp breaker.
- A #14 cooper wire is connected to a 20 amp breaker.
- An incandescent light fixture next to a closet shelf.
- Open knockouts are in an electrical panel. ✔✔A #12 copper wire is connected to a 15 amp
breaker.
A subpanel is a detached building has melted insulation on a neutral conductor. What is the most
likely cause of this condition?
- The neutral conductor is loose at the terminal bar.
- The circuit breaker is defective.
- There is no grounding electrode.
- The circuit breaker ampacity is too large for the wire. ✔✔The neutral conductor is loose at the
terminal bar.
Capillary tubes are near to and attached to the...
- evaporator coil
- heat exchanger
- condenser coil
- compressor discharge ✔✔evaporator coil.
A collar tie is found in:- the attic near the top plate
- the basement between floor joists
- a wall at the intersection of two walls
- the upper third of the rafter length ✔✔the upper third of the rafter length
During your inspection you see small white insects. What do you say to your clients?
- Do not say anything.
- There are termites in this property.
- There is damage to the structure due to an insect infestation.
- Suggest obtaining the services of a pest control operator. ✔✔Suggest obtaining the services of a
pest control operator.
Deck ledger boards with floor joists 16'6'', should be securely attached directly to the house by
- Properly sized lag bolts every 16 inches.
- 16d galvanized nails placed every 16 inches.
- Properly sized joist hangers for the house.
- Properly sized lag bolts into the foundation ledge. ✔✔properly sized lag bolts every 16 inches
Roof truss uplift can cause cracks to form
- above exterior window and doors.
- at interior wall/ceiling intersections.
- in bottom chords of roof trusses.
- in top chords of roof trusses. ✔✔at interior wall/ceiling intersections.
The framing method that uses studs continuously from the sill to the roof is called:
- Post-and-beam construction.
- Balloon framing.
- Platform framing.
- California framing. ✔✔Balloon framing.A scupper would most likely be located in:
- a parapet wall.
- a floor drain.
- an oil furnace vent.
- a K-type gutter. ✔✔A parapet wall
Generally, which type of the item is NOT included in a home inspection?
- Unsafe
- Defective
- Not present
- Cosmetic ✔✔Cosmetic
The primary function of a skimmer is to provide
- a way for water to return to the pump.
- a place to put chlorine tablets.
- a means to remove floating debris from the water.
- a secondary method of filtering the water. ✔✔a means to remove floating debris from the water.
Polybutylene (PB) water supply tubing is seen in the house. You should report that it:
- May require expensive replacement.
- Is illegal to use this kind of pipe.
- Should only have been used for waste pipe.
- Is not a problem. PVC pipe is a problem. ✔✔May require expensive replacement.
The term "wet vent" refers to a:
- Vent that traps water and therefore stays wet.
- Vent located above the roof line and exposed to rain.
- Vent that runs outside an exterior wall.
- Waste line that also functions as a vent. ✔✔Waste line that also functions as a vent.Smelling sewer gas near a bathroom sink indicates that the drain trap is:
- Clogged
- Undersized
- Flooded
- Dried out ✔✔Dried out
Water is dripping from the cold water pipes above a gas water heater. This might be caused by:
- Exhaust spillage.
- Short cycling.
- A cold start.
- Overfiring. ✔✔Exhaust spillage
Where is an S-Trap most likely to be located?
- in a water closet
- near a furnace
- under a kitchen sink
- in a circuit vent ✔✔Under the kitchen sink.
A concrete driveway is 1/2 inch higher that the adjacent concrete walkway. What is the most likely
reason for this condition:
- The walkway is not thick enough.
- The soil under the walkway was not compacted.
- There is no reinforcing steal in the walkway.
- The walkway concreate is not air entrained. ✔✔The soil under the walkway was not compacted
The MAXIMUM acceptable variation in riser heights within a flight of stairs is:
- 1/2 inch.
- 3/8 inch.
- 3/4 inch.
- 1 inch. ✔✔3/8 inch.Relative humidity is expressed as
- volume
- percentage
- capacity
- temperature ✔✔percentage
In order for the soffit vents to operate properly, there MUST be:
- A clear air channel between the roof sheathing and the insulation.
- A turbine vent.
- Vents on both ends on the outside.
- Continuous vent strips on the length of the soffit. ✔✔A clear air channel between the roof
sheathing and the insulation
The home you are currently inspecting has a gas furnace or boiler, each of the following clues may
indicate that the house also may have a abandoned buried oil storage tank, EXCEPT
- 3/8" diameter cooper tubes emerging for the inside of the foundation wall or floor near the furnace
or broiler.
- a 1 1/4" diameter vent pipe outside coming from underground against the house.
- the brick chimney serving the furnace or boiler has dererioted mortar joints at the base.
- your knowledge that the neighborhood had or still has some houses served by oil heat. ✔✔the
brick chimney serving the furnace or boiler has deteriorated mortar joints at the base
What component is involved in controlling when a hot water boiler activates?
- A humidistat.
- A pressuretrol.
- An aquastat.
- A high limit switch. ✔✔An aquastatTwo roof trusses passing above an interior hallway have been cut to install a pull-down attic ladder.
There is no cracking or indication of distress in the walls or ceilings. Which of the following is the
MOST appropriate action?
- This is not a concern since this is no indication of distress.
- This is beyond the scope of an inspection and does not need to be reported.
- The inspector can evaluate the remaining pieces of the trusses as if they were site-built.
- The inspector should recommend this situation be referred to a structural engineer. ✔✔The
inspector should recommend this situation be referred to a structural engineer.
A cast-in-place concrete basement wall has a 1/4 inch wide crack where the wall is bowing slightly.
Brown stains are below the siding. What is the most likely reasons for this condition?
- The exterior drainage is poor.
- The wall contains 5/8 inch reinforcing steel.
- The concrete was not properly vibrated.
- The wall damp proofing was improperly installed. ✔✔The exterior drainage is poor
The functions of screened metal chimney caps include all of the following EXCEPT:
- Slowing the draft that accelerates at the top o the flue.
- Preventing the escape of sparks and embers.
- Preventing the entry of birds and other animals.
- Retarding rainwater penetration into the flue. ✔✔Slowing the draft that accelerates at the top of
the flue
The joints on the exterior of the brick chimney should be:
- Concaved.
- Raked.
- Open.
- Closed. ✔✔Concaved
The MOST common color coding for 240V current-carrying conductors in a multi-conductor cable
is:- black neutral, white ground and green hot.
- black and white hot and green ground.
- black and red hot and white for neutral.
- black and red hot and a green ground. ✔✔Black and Red Hot and White for neutral
The ampacity of copper-clad aluminum is:
- the same as for cooper wiring.
- higher than for copper wiring.
- the same as for the aluminum wiring.
- lower that for aluminum wiring. ✔✔The same as for aluminum wiring.
How many energized conductors supply 240-volt, 200-amp single phase electric service?
- 1
- 2
- 3
- 4 ✔✔2
A circuit breaker's job is to:
- protect inhabitants by limiting shock duration.
- regulate power to the attached equipment.
- protect wiring from an electrical overload.
- measure the current in a circuit. ✔✔Protect wiring from an electrical overload
Looking into an open electric service panel you see a wire with charred insulation. What should
you do?
- You are not responsible for removing electric service panel so this situation will never occur.
- Check the wire to see if it is hot and then tighten and loose connections.
- Disconnect the wire, cut the burned area off, and strip and reconnect the wire.
- Report on the condition, and inform the homeowner that an electrician should repair. ✔✔Report
on the condition, and inform the homeowner that an electrician should repair.Which of the following locations would be the best for a thermostat for a heat pump in the cooling
mode?
- Interior hallway
- Kitchen near a supply vent
- Basement near the air handler
- Master Bedroom ✔✔Interior hallway
On a previous work day, you left the cover off of the access to the crawl space. A person fell the
next day and was injured. Which of the following insurance types will be used to pay damages?
- Bonding
- General liability
- Errors and omissions and broker liability
- Claims made and occurrence ✔✔General liability
A Home inspection agreement is most likely to be interpreted using which law?
- Federal
- State
- Country
- Parish ✔✔State
The inclusion of photographs in a report is
- optional.
- mandatory.
- discriminatory.
- illegal. ✔✔optional
During an inspection of a gas dryer, you observe no exhaust vent. Your report should:
- Recommend installing a metal dryer vented to the exterior.
- Recommend installing a flexible plastic dryer duct vented to the exterior.
- Indicate a code violation and state that corrective action should be taken.- Indicate that is not a problem. ✔✔Recommend installing a metal dryer duct vented to the exterior
Egress window well requires a ladder when the wall is deeper than:
- 24 inches
- 32 inches
- 44 inches
- 56 inches ✔✔44 inches
The MINIMUM width of stairways (not considering railings) is:
- 27 inches
- 36 inches
- 42 inches
- 44 inches ✔✔36 inches
When installing flexible supply air ducts under a floor joist space, the minimum requirement for
proper strapping sequence is generally:
- 1 1/2" wide and at 4' spacing
- 3/4" wide and 6' spacing
- 1 1/2" wide and 6' spacing
- 3/4" wide and 4' spacing ✔✔1 1/2" wide and at 4' spacing
Which of the following is not a component of a staircase?
- Riser
- Header
- Stringer
- Tread ✔✔Header
A 1/2 inch wide gap exists between the drywall wall and ceiling. The seller reports that this gap
opens in the winter and closes in the summer. What is the most likely cause of this condition?- Truss uplift
- A damaged truss bottom chord
- Poor drywall finishing
- An absent gusset plate ✔✔Truss uplift
Is there a safety issue with the installation of this egress window well?
- No issue, there is evidence of an egress ladder
- Yes, there is what appears to be more than 4" spacing between the balusters
- No, there is not a guard installed since there is a ladder
- Yes. There is not gate installed on the open end of the well. ✔✔Yes. There is not gate installed
on the open end of the well.
Which is the most acceptable fastener for connecting a deck ledger to a rim joist?
- 5/8 inch diameter stainless steel carriage bolt.
- 1/2 inch diameter electroplated galvanized steel wood screw.
- 1/2 inch diameter hot-dipped galvanized steel machine bolt.
- 5/8 inch diameter brass machine screw. ✔✔1/2 inch diameter hot-dipped galvanized steel
machine bolt.
A new home you are inspecting has a below grade finished basement including a bedroom. You
should verify presence of a smoke detector and a:
- second means of egress
- carbon monoxide alarm
- fire extinguisher
- fully adjustable heat vent ✔✔second means of egress
Buckling in a horizontal vinyl siding is generally caused by:- Reflected sunlight
- Improper fastening
- Condensation within the wall
- Improper house wrap ✔✔Improper fastening
All vertical joints of panel sheathing shall occur over:
- fire blocking
- studs
- braced walls
- window headers ✔✔studs
For an asphalt shingle roof installed over an existing asphalt shingles, leakage commonly occurs
at:
- eaves
- penetrations
- ridges
- hips ✔✔penetrations
From this photo the roofing material is likely to be:
- 3 tab fiberglass shingles
- Rolled Roofing
- Wood Shingles
- Wood Shakes ✔✔Wood Shakes
The closet where the water heater is located was locked. Hot water was available where required.
The best way to report this situation is the water heater:- was inaccessible
- closet door was locked
- was functioning properly
- was not inspected because the door was locked ✔✔was not inspected because the door was
locked
What information usually required when reporting a faulty component?
- The component's location
- The deficiency's implications
- The building code section violated
- The component's age ✔✔The deficiency's implication
[Show More]