Home Inspector National Exam
Questions and Answers Rated A
There shall be a wall switch at each floor to control stairway lighting where the stairway has _____
or more risers ✔✔6
Bathtubs should be equipped with the
...
Home Inspector National Exam
Questions and Answers Rated A
There shall be a wall switch at each floor to control stairway lighting where the stairway has _____
or more risers ✔✔6
Bathtubs should be equipped with the waste outlets and overflow outlets connected to piping at
least _____ inches in diameter ✔✔1.5 inches
Doors between the garage and residence shall be equipped with a ✔✔Self-closing door
The _____ shall not be considered as an effective ground-fault current path ✔✔Earth
For natural ventilation for habitable rooms, the min openable area to the outdoors shall be _____
percent of the floor area being ventilated ✔✔4%
Fuel gas appliance connectors shall not exceed an overall length of _____ feet ✔✔6 ft.
What size are fuel-gas-fired domestic clothes dryer ducts ✔✔4 inches
The maximum amount of fuel oil stored above ground or inside a building shall be _____ gallons.
✔✔660 gals.
The minimum bet area of ventilation openings shall not be less than _____ square foot for each
_____ square feet of under-floor space ✔✔1 sqft. for each 150 sqft
Foundation anchor bolts shall be at least _____ inch in diameter and shall extend a minimum of
_____ inches into concrete or grouted cells of concrete masonry units ✔✔1/2 in. , 7 in.Outdoor and return air for a forced-air heating and cooling system shall not be taken from
✔✔Closets, bathrooms, toilet rooms, kitchens, garages, boiler rooms, furnace rooms,
unconditioned attics, or other dwelling units
Receptacles installed on 15 and 20 ampere rated branch circuits shall be on the _____ type
✔✔Grounding
Ceiling-suspended paddle fans shall be supported ________________ of the outlet box.
✔✔independently
Dwelling units shall be provided with heating facilities capable of maintaining a minimum room
temperature of ✔✔68 *f
Conductors in NM cable assemblies shall be rated at _________ Celsius. ✔✔90 *C
Address numbers shall be a minimum of _____ inches high with a minimum stroke width of _____
inch. ✔✔4 inches , 1/2 inch
Habitable space, hallways, corridors, bathrooms, toilet rooms, laundry rooms and portions of
basements containing these spaces shall have a ceiling height of not less than _______ feet. ✔✔7
feet
A Type B or a Type L gas vent shall terminate at least _____ feet in vertical height above the
highest connected APPLIANCE DRAFT HOOD or FLUE COLLAR. ✔✔5 feet
Open web truss or I-Joist floor assemblies require a ____-inch gypsum wallboard membrane,
____-inch wood structural panel membrane, or the equivalent on the underside. ✔✔1/2 And 5/8
Flanges and lips of load-bearing cold-formed steel floor framing members shall not be cut or ____.
✔✔NotchedGas vents over 12 inches in size shall terminate not less than _____ feet above the highest point
where they pass through the roof. ✔✔2 feet
Foundations for masonry chimneys shall be constructed of concrete or solid masonry at least _____
inches thick ✔✔12 inches
Supports and foundations for the outdoor unit of a heat pump shall be raised at least ___ inches
above the ground. ✔✔3 inches
Attic ventilation openings shall have a least dimension of _________ inch minimum to _________
inch maximum openings. ✔✔1/16 And 1/4
All wood beams, joists, studs and other combustible material shall have a clearance of not less
than _____ inches from the front faces and sides of masonry fireplaces. ✔✔2 inches
The minimum headroom in all parts of the stairway shall not be less than _____ feet, _____ inches
✔✔6 feet, 8 inches
[Show More]