Construction and The Built Environment > QUESTIONS & ANSWERS > Home Inspection - National Prep Exam Questions and Answers Already Graded A (All)

Home Inspection - National Prep Exam Questions and Answers Already Graded A

Document Content and Description Below

Home Inspection - National Prep Exam Questions and Answers Already Graded A The main difference between a laundry tub pump and a sump pump is (a) laundry tub pumps can handle lint (b) sump pumps ... are laundry capacity (c) laundry tub pumps operate on 120 volt, and sump pumps operate only on 240v power (d) sump pumps are manual, and laundry tub pumps are automatic ✔✔(a) laundry tub pumps can handle lint All of the following are common HRV problems except (a) missing filters (b) dirty heat exchanger core (c) lack of a trap in the condensate drain (d) flow measuring stations located on warm side ducts ✔✔(d) flow measuring stations located on warm side ducts Squeaking subflooring is an indication of (a) over spanned joists (b) undersized beams (c) poor fastening of subfloors (d) undersized subfloors ✔✔(c) poor fastening of subfloors High efficiency gas furnaces installed in old ductwork tend to have(a) higher maintenance (b) excess temperature rise (c) shorter life spans (d) all of the above ✔✔(c) shorter life spans Most radiant heating systems are located (a) in the ceiling (b) in the floors (c) on exterior walls below windows (d) in light weight concrete panels ✔✔(a) in the ceiling Which group of terms does not go together? (a) pier, column, truss (b) rafter, truss, purlin (c) joist, beam, girder (d) stud, header, sill ✔✔(a) pier, column, truss The cable is protected by 60-amp breakers at the main panel. You should make sure that (a) the cable is protected in a ventilated metal raceway (b) the cable is in rigid conduit (c) the cable is no longer than three feet (d) the subpanel is rated to handle at least 60 amps. (d) the subpanel is rated to handle at least 60 amps. ✔✔(d) the subpanel is rated to handle at least 60 amps. If there is no water in the boiler, the low water cutouts prevents the(a) circulator from operating (b) burner from firing (c) pressure reducer from adding water (d) entrapment of air in the air separator ✔✔(b) burner from firing A house has service entrance conductors designed for 100 amps and a main disconnect rated at 100 amps. Which of these conditions is unsafe? (a) The service entrance box is rated at 125 amps (b) The service box is rated at 75 amps (c) The distribution panel is rated at 125 amps (d) The distribution panel is rated at 200 amps ✔✔(b) The service box is rated at 75 amps [Show More]

Last updated: 2 years ago

Preview 1 out of 28 pages

Buy Now

Instant download

We Accept:

We Accept
document-preview

Buy this document to get the full access instantly

Instant Download Access after purchase

Buy Now

Instant download

We Accept:

We Accept

Reviews( 0 )

$8.00

Buy Now

We Accept:

We Accept

Instant download

Can't find what you want? Try our AI powered Search

158
0

Document information


Connected school, study & course


About the document


Uploaded On

Nov 16, 2022

Number of pages

28

Written in

Seller


seller-icon
Alphascore

Member since 2 years

48 Documents Sold

Reviews Received
0
4
2
2
3
Additional information

This document has been written for:

Uploaded

Nov 16, 2022

Downloads

 0

Views

 158

Document Keyword Tags


$8.00
What is Scholarfriends

In Scholarfriends, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Scholarfriends · High quality services·