Home Inspection Exam Prep Questions
and Answers Graded A+
Ceiling joist when installed parallel to roof rafters, to prevent rafter spread, should be overlapped...
- 3 inches
- 4 inches
- 5 inches
- 6 inches ✔✔3 inc
...
Home Inspection Exam Prep Questions
and Answers Graded A+
Ceiling joist when installed parallel to roof rafters, to prevent rafter spread, should be overlapped...
- 3 inches
- 4 inches
- 5 inches
- 6 inches ✔✔3 inches
What is the primary purpose of the control joints placed in concrete driveways?- To prevent
cracking.
- To drain the surface.
- To reduce random cracking.
- To enhance appearance. ✔✔To reduce random cracking
Which of the following is an indication that a masonry wall is veneer and NOT structural?
- No bond courses are seen.
- The lintels are made of steel
- The windows are inset 6" from the wall face.
- There are no arches in the wall. ✔✔No bond courses are seen.
Which roof covering is most appropriate for a roof with a slope of 1 1/2:12 above a single-family
house? Assume standard installation of any required underlayment.
- Metal shingles.
- Wood shakes.
- Modified bitumen.
- Slate shingles. ✔✔Modified bitumen
Historically, spaced or skip sheathing has been used for roof decking because it...- is economical and strong
- provides a safe walking platform
- allows for drying of roof material
- retards attic ventilation ✔✔Allows for drying of roof material.
What is the bare minimum for inspecting a roof?
- Walking on the roof.
- Viewing the roof from ladder at one location.
- Viewing the roof from the ground.
- Viewing the roof from the a ladder at multiple locations. ✔✔Viewing the roof from the ground.
The water heater pressure relief valve discharge pipe MUST be:
- A 3/4 inch pipe
- Made of rigid pipe
- Threaded at the bottom
- As least the normal size of the relief valve outlet ✔✔As least the nominal size of the relief value
outlet.
Permeability is the property of a material that allows the passage of:
- Water vapor.
- Heat energy.
- Liquid Water.
- Infrared radiation. ✔✔Water vapor
Which is the best example of the heat flow by conduction?
- Heat flowing from the water inside to the body of a radiator.
- Heat flowing from a forced-air supply register.
- Heat flowing from a steam boiler inside pipes.
- Heat flowing from a floor furnace. ✔✔Heat flowing from the water inside to the body of the
radiator.Is bonding jumper needed for a gas hot water tank?
- Yes, To eliminate stray voltage that could electrify the water in the tank.
- Yes, Bonding jumpers ensure a continuous ground path even when the water heater is removed.
- No, it is not required since the house is effectively bonded through the grounding electrode
- Yes, the bonding jumper is installed strictly for lightening protection. ✔✔Yes, Bonding jumpers
ensure a continuous ground path even when the water heater is removed.
In new construction, which of the following items would NOT be considered an electrical system
defect?
- A #12 cooper wire is connected to a 15 amp breaker.
- A #14 cooper wire is connected to a 20 amp breaker.
- An incandescent light fixture next to a closet shelf.
- Open knockouts are in an electrical panel. ✔✔A #12 copper wire is connected to a 15 amp
breaker.
A subpanel is a detached building has melted insulation on a neutral conductor. What is the most
likely cause of this condition?
- The neutral conductor is loose at the terminal bar.
- The circuit breaker is defective.
- There is no grounding electrode.
- The circuit breaker ampacity is too large for the wire. ✔✔The neutral conductor is loose at the
terminal bar.
Capillary tubes are near to and attached to the...
- evaporator coil
- heat exchanger
- condenser coil
- compressor discharge ✔✔evaporator coil.