EPA 608 Practice exam type 1 solved
correctly
The sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. ✔✔Restricted to
technicians who are EPA certified and refrigerant recovery
A small Pliance is define
...
EPA 608 Practice exam type 1 solved
correctly
The sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. ✔✔Restricted to
technicians who are EPA certified and refrigerant recovery
A small Pliance is defined as a system that is ✔✔Manufactured, fully charged, and hermetically
sealed in a factory with a charge of 5 pounds or less
A __________ recovery device can be use for type 1 small appliance applications or type 2
applications if the total charge is below 15 pounds. ✔✔System dependent
You must have a self-contained recovery machine available unless you only work on ✔✔Small
appliances
Recovery devices for use with small appliances must be capable of ✔✔Recovering 90% of the
refrigerant when the compressor is operating
The hydrocarbon refrigerant approved for retrofit into existing household refrigerators is
✔✔None. Hydrocarbons are not approved for any retrofit applications
New household refrigerators with a charge of less than 57 grams (2 ounces weight) can use any
of the following refrigerants, except. ✔✔R-1235yf
And exempt refrigerant is any refrigerant that has a 0 Ozone depletion potential (0 ODP) any
global warming potential (GWP) equal to or lower than carbon dioxide, that is a GWP of
_________ or less. ✔✔1
What is not a small appliance? ✔✔An MVAC-like system that holds 3 pounds of R-22
Any system with a charger less than ________ pounds can you system dependent recovery
equipment. ✔✔15
Anytime pressurized nitrogen is put into the system, the nitrogen gas ✔✔Maybe vented to the
ambient air
When a tank of mixed refrigerant is sent to a reclaimer, they can ✔✔Either refuse to except the
refrigerant or charge extra for processing it
A passive system dependent recovery process ✔✔Recovered refrigerant in a non-pressurized
container
What is the pressure of a storage cylinder of R-134A, that is stored in a room where the
temperature is 100°F? ✔✔124 PSIG
What is the pressure of a storage cylinder of R-404A, that is stored in a room where the
temperature is 100°F? ✔✔237 psig
Any refrigerant that is vented off the top of the charging cylinder ✔✔Must be recovered
Recovery of refrigerant cannot begin if the initial pressure in the system is ✔✔0 psig
What is the pressure of the storage cylinder of R-410a, that is stored in a room where the
temperature is 100°F? ✔✔319 psig
To reach the necessary recovery level, when using a ________, it will most likely be essential to
heat and strike the compressor with a rubber mallet to release any refrigerant. ✔✔Passive
recovery devices on a small appliance with a non-operating compressor
You must know the ________ before beginning a refrigerant recovery. ✔✔Type of refrigerant
that is in the system
Nitrogen tanks should always be equipped with a ________. ✔✔Pressure regulator and pressure
relief valve downstream of the regulator
If a large leak of refrigerant occurs, __________. ✔✔Immediately vacate in naturally ventilate
the area
A very large refrigerant leak can cause Suffocation because refrigerants ✔✔Are heavier than air
and displace oxygen
Always _____________ when connecting or disconnecting refrigeration hoses. ✔✔1.) wear
safety eyewear and butyl-lined gloves 2.) verify the hoses are rated for the refrigerant being used
3.) avoid trapping liquid refrigerant in the hoses
CFC and HCFC refrigerants can decompose to form ✔✔Hydrochloric and hydrofluoric acids
Applying heat, with a heat gun, to the compressor; ✔✔Can help vaporize any trapped liquid
refrigerant during recovery.
Which HC refrigerant is allowed for use in new domestic small appliances? ✔✔R-600a
Technicians who perform sealed system service on small points is must have ✔✔Type 1 or
universal certification
Recovering multiple types of refrigerant in the same cylinder; ✔✔Will make the reclaimed
refrigerants unreclaimable
Type one certification is required for; ✔✔Persons handling refrigerant during maintenance,
service, or repair of small appliances.
Recovery equipment must be ✔✔Certified by an EPA approved testing laboratory
When filling a charging cylinder with a regulated refrigerant; ✔✔The refrigerant vapor that is
vented off the top of the cylinder must be recovered.
Which of the following is true regarding refrigerant leaks one small appliances? ✔✔EPA does
not require repair, but leaks should be repaired whenever possible.
If a strong odor is detected while performing a refr