Environmental Science > QUESTIONS & ANSWERS > EPA 608 Practice exam type 1 solved correctly (All)
EPA 608 Practice exam type 1 solved correctly The sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. ✔✔Restricted to technicians who are EPA certified and refrigerant recovery A ... small Pliance is defined as a system that is ✔✔Manufactured, fully charged, and hermetically sealed in a factory with a charge of 5 pounds or less A __________ recovery device can be use for type 1 small appliance applications or type 2 applications if the total charge is below 15 pounds. ✔✔System dependent You must have a self-contained recovery machine available unless you only work on ✔✔Small appliances Recovery devices for use with small appliances must be capable of ✔✔Recovering 90% of the refrigerant when the compressor is operating The hydrocarbon refrigerant approved for retrofit into existing household refrigerators is ✔✔None. Hydrocarbons are not approved for any retrofit applications New household refrigerators with a charge of less than 57 grams (2 ounces weight) can use any of the following refrigerants, except. ✔✔R-1235yf And exempt refrigerant is any refrigerant that has a 0 Ozone depletion potential (0 ODP) any global warming potential (GWP) equal to or lower than carbon dioxide, that is a GWP of _________ or less. ✔✔1 What is not a small appliance? ✔✔An MVAC-like system that holds 3 pounds of R-22 Any system with a charger less than ________ pounds can you system dependent recovery equipment. ✔✔15 Anytime pressurized nitrogen is put into the system, the nitrogen gas ✔✔Maybe vented to the ambient air When a tank of mixed refrigerant is sent to a reclaimer, they can ✔✔Either refuse to except the refrigerant or charge extra for processing it A passive system dependent recovery process ✔✔Recovered refrigerant in a non-pressurized container What is the pressure of a storage cylinder of R-134A, that is stored in a room where the temperature is 100°F? ✔✔124 PSIG What is the pressure of a storage cylinder of R-404A, that is stored in a room where the temperature is 100°F? ✔✔237 psig Any refrigerant that is vented off the top of the charging cylinder ✔✔Must be recovered Recovery of refrigerant cannot begin if the initial pressure in the system is ✔✔0 psig What is the pressure of the storage cylinder of R-410a, that is stored in a room where the temperature is 100°F? ✔✔319 psig To reach the necessary recovery level, when using a ________, it will most likely be essential to heat and strike the compressor with a rubber mallet to release any refrigerant. ✔✔Passive recovery devices on a small appliance with a non-operating compressor You must know the ________ before beginning a refrigerant recovery. ✔✔Type of refrigerant that is in the system Nitrogen tanks should always be equipped with a ________. ✔✔Pressure regulator and pressure relief valve downstream of the regulator If a large leak of refrigerant occurs, __________. ✔✔Immediately vacate in naturally ventilate the area A very large refrigerant leak can cause Suffocation because refrigerants ✔✔Are heavier than air and displace oxygen Always _____________ when connecting or disconnecting refrigeration hoses. ✔✔1.) wear safety eyewear and butyl-lined gloves 2.) verify the hoses are rated for the refrigerant being used 3.) avoid trapping liquid refrigerant in the hoses CFC and HCFC refrigerants can decompose to form ✔✔Hydrochloric and hydrofluoric acids Applying heat, with a heat gun, to the compressor; ✔✔Can help vaporize any trapped liquid refrigerant during recovery. Which HC refrigerant is allowed for use in new domestic small appliances? ✔✔R-600a Technicians who perform sealed system service on small points is must have ✔✔Type 1 or universal certification Recovering multiple types of refrigerant in the same cylinder; ✔✔Will make the reclaimed refrigerants unreclaimable Type one certification is required for; ✔✔Persons handling refrigerant during maintenance, service, or repair of small appliances. Recovery equipment must be ✔✔Certified by an EPA approved testing laboratory When filling a charging cylinder with a regulated refrigerant; ✔✔The refrigerant vapor that is vented off the top of the cylinder must be recovered. Which of the following is true regarding refrigerant leaks one small appliances? ✔✔EPA does not require repair, but leaks should be repaired whenever possible. If a strong odor is detected while performing a refr [Show More]
Last updated: 2 years ago
Preview 1 out of 7 pages
Buy this document to get the full access instantly
Instant Download Access after purchase
Buy NowInstant download
We Accept:
[SOLVED] EPA BUNDLED EXAMS QUESTIONS AND ANSWERS WITH VERIFIED SOLUTIONS
By Nutmegs 2 years ago
$20
17
Can't find what you want? Try our AI powered Search
Connected school, study & course
About the document
Uploaded On
Jan 02, 2023
Number of pages
7
Written in
All
This document has been written for:
Uploaded
Jan 02, 2023
Downloads
0
Views
115
Scholarfriends.com Online Platform by Browsegrades Inc. 651N South Broad St, Middletown DE. United States.
We're available through e-mail, Twitter, Facebook, and live chat.
FAQ
Questions? Leave a message!
Copyright © Scholarfriends · High quality services·