CSLB C20 Trade Tougher Questions and
Answers with Complete Solutions
Duct systems should be installed according to ____ Standards ✔✔SMACNA
The type of flue pipe used on gas 80% standard furnace venting systems serving
...
CSLB C20 Trade Tougher Questions and
Answers with Complete Solutions
Duct systems should be installed according to ____ Standards ✔✔SMACNA
The type of flue pipe used on gas 80% standard furnace venting systems serving gas fired
systems ✔✔Type B-Vent
Which type of gauge would you use for very high vacuums? ✔✔McLeod type gauge
How many BTUs are equal to one kilowatt hour ✔✔3,414 BTU
When adjusting gas fired furnaces above 2000 feet, the BTU per hour input should be reduced
4% for each _____ feet above sea level. ✔✔4% for every 1,000 feet
How are residential furnace blower motors classified ✔✔by starting method
What is the equation for determining heat loss through a material ✔✔Q = U times A times TD
What is the overfire rating on a small draft hood ✔✔0.02 inches
what is the equation for determining minimum size air supply for a blower type furnace ✔✔2
divided by 1000 times the BTU of the furnace
what is the equation for determining minimum size air supply for a gravity type furnace ✔✔7
divided by 1000 times the BTU of the gravity furnace
the type of bub that measures evaporative cooling ✔✔wet bulb
the heating value of natural gas is ✔✔1100 BTU per cubic foot
Silver solder starts to flow at or above ✔✔1150 degrees fahrenheit
how high must a 12"diameter flue pipe project above a pitched roof line ✔✔2 feet
Ducts conveying flammable dusts must have a clearance from combustible materials of not less
than how many inches ✔✔18 inches
A furnace installed in an attic must have a minimum access opening of ✔✔22 by 30 inches
The Cal Osha exposure limit for asbestos is ____ f cc ✔✔0.1 f cc
If the asbestos content of a material encountered at a work site exceeds 1%, what should you do?
✔✔put up a caution sign and close off the affected area
On a residential system that uses more than 50 pounds of freon, what is the maximum annual
leakage rate allowed before repairing the leak is mandatory. What is it for commercial? ✔✔15%,
35%
what is the minimum safe landing clearance diameter for a helicopter? ✔✔200 feet
what is the max flexible connector you can use for a heating furnace ✔✔3 feet
what is the boiling point of R22 at atmospheric pressure? ✔✔negative 41 degrees
what is the minimum clearance between an air duct an a rafter ✔✔1 inch
why should there be clearance between an air duct and a rafter? ✔✔fire safety purposes
for most refrigerants, is the the boiling point above or below zero degrees Fahrenheit? ✔✔below