NCCER Electrical 1 Module 10 Questions
and Answers Graded A
Blue Prints ✔✔An exact copy of reproduction of an original drawing
Floor plan ✔✔As viewed from above
Site plan ✔✔Location of building on the property
Surve
...
NCCER Electrical 1 Module 10 Questions
and Answers Graded A
Blue Prints ✔✔An exact copy of reproduction of an original drawing
Floor plan ✔✔As viewed from above
Site plan ✔✔Location of building on the property
Surveys show ✔✔All property lines, existing public utilities and their location on or near the
property
Elevation drawings show ✔✔The exterior face of the building
Floor plans are in ✔✔2 dimension, length and width
Topographic survey shows ✔✔Property lines, contour lines, notes and symbols
Sectional view ✔✔Is a cutaway view that shows the inside of the building
Title block ✔✔A table located in the bottom right-hand corner of an engineering drawing that
identifies, in an organized way, all of the necessary information that is not given on the drawing
itself. Also referred to as a title strip.
Revision Block ✔✔Shows modifications or redrawn drawings
Architectural scale ✔✔1/16" = 1', 1/8" = 1' 1/4" = 1
Engineer scale measurements ✔✔1"=10 units through 1"=100 units
Metric scale 1:1 to 1:100 ✔✔Millimeters are used
Metric scale 1:200 to 1:2000 ✔✔Meter is used
CAD ✔✔Computer aided design
Masterformat ✔✔Most common used writing format
Division 26 is ✔✔Electrical
Division 27 is ✔✔Communications
Division 28 is ✔✔Electronic safety and security
ANSI ✔✔American National Standards Institute
The type of lighting fixture is identified by ✔✔A numeral placed inside a triangle or other
symbol and placed near the fixture to be identified
A section line on a drawing shows ✔✔The location of the section on the plan
In a drawing with dimension lines the values shown inside the lines are ✔✔The actual
dimensions
Dashed lines are used to represent a branch circuit on a drawing mean that the wiring is to be
✔✔Concealed in the floor
And electrical drafting line with a double arrowhead represents ✔✔A branch circuit homerun
To meet general recommendations a residential branch circuit rated for 2400 VA should have a
connected load of no more than ✔✔1,920VA
Power riser diagrams are used to show the ✔✔Arrangement of electric service equipment
The symbols T1 T2 and T3 in a typical motor starter schematic represent ✔✔Motor terminals
The current master format standard covering communications systems is under ✔✔Division 27
Title Block on electrical drawing includes ✔✔Name of the project, address of the project, name
of the owner of client, name of the architectural firm, date of completion, scale, initials of the
drafter, checker, and designer with dates under each, job number, sheet number, general
description of the drawing
A power riser diagram is a type of ✔✔Block diagram
Schematic diagrams ✔✔Normally used only in complicated electrical systems such as control
circuits components are represented by symbols
Branch circuit layout for lighting ✔✔Ex. 15A x 120V=1800VA 80% of 1800VA 0.8x1800VA=
1,440VA
Power riser diagram ✔✔Single line block diagram used to indicate the electrical service
equipment, service conductors, feeders and subpanels
A _______ is a systematic way of presenting equipment lists in a drawing in tabular form
✔✔Schedule
Low voltage switch ✔✔SL
Existing power lines ✔✔P
Division 25 ✔✔Integrated automation
One line / single line diagram ✔✔shows the path of an electrical circuit
Height of front rear or sides of a building are shown in a ✔✔Elevation drawing
The specific types of luminaries required in an illustration can be found on the ✔✔Lighting
fixture schedule