Nichole’s Math Board Review Exam - Questions, Answers and Explanations A patient treatment with 2 fields separated by 120 degrees, likely needs a ____ degree wedge inserted for even dose distribution. 30 degrees Use the
...
Nichole’s Math Board Review Exam - Questions, Answers and Explanations A patient treatment with 2 fields separated by 120 degrees, likely needs a ____ degree wedge inserted for even dose distribution. 30 degrees Use the hinge angle formula. A patient is treated using the SAD technique on a 100cm isocentric linac. The field size is 24 x 20. The iso is located 5cm below the patient's skin surface. What does the field measure on the patient's skin? 23 x 19 Use direct proportion. Adjacent fields with respective lengths of 40cm and 36cm should intersect at a depth of 10cm. The patient will be treated on a 100cm isocentric accelerator using the SSD technique. Calculate the skin gap. 3.8 cm Gap formula is L/2 (d/SSD) for field one + L/2 (d/SSD) for field two. The range in water of a 20 MeV electron beam is approximately ___ cm. 10 cm The range of an electron beam is found by dividing the energy by 2. The output of a 7 MeV electron beam, 12 x 12 cm field is 1.01 cGy / MU. Calculate the MUs required to deliver 250 cGy to the depth of the 90% dose line. 275 MU Use the MU formula for SSD technique. The depth of the 80% dose line for a clinical electron beam energy is given by what fraction of the energy? 1/3 of the energy The depth of the 80% dose line is found by dividing the energy by 3. Using a 100cm SAD machine, an anterior SSD reading of 86.5 cm, and posterior SSD reading of 85.5 cm are given. The total anterior to posterior separation along the central axis is ___ cm. 28 cm The separation can be found by adding the depths of isocenter in parallel opposed fields. 13.5 + 14.5 = 28 Calculate the equivalent square for a rectangular field 10 x 15. 12 cm Use Sterling's formula. Calculate the mag factor for an object measuring 6cm on a film. The SOD was 70cm and the SFD was 100cm. 1.43 Use the magnification formula ... SFD / SOD = magnification Rotational arc therapy is elected for treatment to the pituitary gland. The arc is 240 degrees and the calculated MUs are 196 MU. The MU / degree setting will be ... 0.817 To calculate the MU / degree: 196 MU / 240 degrees = 0.817 MU / degree The linac dose rate is 250 MU/minute. What will be the treatment time (in seconds) for a treatment field receiving 100 MU? 24 seconds At 250 MU / minute, using direct proportion it will take 0.4 minutes to deliver 100 MU. Convert the 0.4 minutes to 24 seconds also using direct proportion. A 6 MV photon beam on the linac has an output at iso of 1.2 cGy / MU. What would be the inverse square factor used in the MU calculation for an extended distance treatment at 120 cm SSD? 0.677 The inverse square factor is (SAD / SSD + Dmax)^2. Using this formula, the inverse square factor would be 0.677. A 6 MV photon beam on the linac has an output at iso of 1.2 cGy / MU. What is the output at an extended distance of 120 cm? 0.8124 The new output can be found by multiplying the old output by the inverse square factor 0.677. Use the inverse square formula. The dose rate on a linac is 200 MU / minute. How many minutes long is a treatment requiring 240 MU? 1.2 minutes Use direct proportion. During verification placement imaging for radioactive needles, the image receptor is located 120cm from the source. The 3-inch needles measure 4.0cm on the film. How far away (in cm) were the needles from the image receptor? 30 cm Using direct proportion and magnification rules: 4/3 = magnification and 120 / SAD = magnification. By substitution 4/3 = 120 / SAD. SAD = 90 cm, therefore, the needles had to be 30 cm from the image receptor. Draw a diagram to visualize. A 200-degree rotational arc will be used to treat a pituitary adenoma. The prescribed dose is 180 cGy / day. The daily cGy / degree setting will be ... 0.90 The cGy per degree can be found by dividing the cGy by the rotation degrees. 180/200 = 0.90 cGy / degree. The treatment plan for an esophagus calls for a total dose of 3000 cGy to the AP field, 1500 cGy to the RPO field, and 1500 cGy to the LPO field. The prescription is for a total of 6000 cGy to be delivered in 40 fractions. What will the daily dose be to each field AP : RPO : LPO? 75 : 37.5 : 37.5 This plan calls for unequal weighting. Each fraction should deliver a total of 150 cGy. The AP field is weighted at 50% of the total. 150 x 50% = 75. The remaining 75 will be equally distributed between the oblique fields. 75/2 = 37.5. Dose for each field should total 150 cGy. A dose of 300 cGy was to be delivered to the thoracic spine at 95cm SSD. An error caused treatment to be given at an SSD of 92 cm. The actual dose delivered was ... 320 The inverse square law applies here. 300 (95/92)^2 = 320. What thickness of cerrobend would be equivalent to 5 cm of lead? 6.0 Cerrobend is about 15% less dense than lead. To figure the equivalent attenuation of cerrobend to lead, use the factor 1.2. 1 cm lead
[Show More]