Firefighter 2 Final Exam Latest 2022 (Real Exam Test
Questions 1-100 (456) Already Passed
Which pneumatic tools are often used for delicate cutting operations and can cut case hardened locks and
steel? Correct Answer-
...
Firefighter 2 Final Exam Latest 2022 (Real Exam Test
Questions 1-100 (456) Already Passed
Which pneumatic tools are often used for delicate cutting operations and can cut case hardened locks and
steel? Correct Answer-Whizzer saws
Which proportioning method uses an external pump or head pressure to force foam concentrate into the
fire stream at the correct ratio for the water flow? Correct Answer-Premixing method
What is the term used to describe forward velocity pressure at a discharge opening while water is flowing?
Correct Answer-Flow pressure
Which of the following is NOT a question that would be asked concerning appliances during a residential
fire safety survey?
Are surge protectors being used?
Are appliances name brand?
Are electrical cords in good condition?
Are the units operating properly? Correct Answer-are appliances name brand?
Which type of pressure can be measured with a pitot tube and gauge? Correct Answer-Flow pressure
Proportioning methods: When would batch mixing not be effective? Correct Answer-On large incidents
because attack lines must be shut down when refilling an empty tank.
Water applied to ordinary combustibles usually _______. Correct Answer-Reduce flame spread
Which type of valves are used to control the flow from the hydrant? Correct Answer-Gate valves
The _____ the wood, the easier to ignite and the faster it loses structural integrity. Correct Answer-Smaller
The threads on pump male discharge outlets are protected by fittings called _____ _____. Correct AnswerHose caps
Who should begin stabilization of a patient trapped inside a vehicle? Correct Answer-A rescuer with EMT
training
Name one element of patient removal: Correct Answer-Covering sharp edges
Fixed-temperature heat detectors rated at _____(*f)(*c) are common for living spaces. Correct Answer165 | 76
Cribbing is most commonly used to _________. Correct Answer-stabilize objects
Which type of test should be preformed by private contractors or fire department personnel? Correct
Answer-Standard testing
Which proportioning method is used with portable extinguishers, wheeled, extinguishers, skid-mounted
twin-agent units, and vehicle mounted tank systems? Correct Answer-Premixing method
One of the most important practices to address to building occupants about fire safety is _______. Correct
Answer-making sure to maintain clear and unobstructed exit pathways
Normal pressure exiting a system before water is released from a hydrant is called ______. Correct
Answer-Static presssure
Energy created by moving parts on machines, such as belts and bearings Correct Answer-Mechanical heat
energy
Water received from treatment facilities is delivered to ________ storage tanks before being distributed
throughout the area served. Correct Answer-elevated
State 3 facts about service testing: Correct Answer-1. The test area should be smooth and free from rock
and debris
2. Hose should be tested in a paved area with room to lay out the hose
3. A water source sufficient for filling the hose is necessary
Describe Completed Foam: Correct Answer-completed product after air is introduced into the foam
solution
What can hide fire hazards and impede paths of egress? Correct Answer-poor housekeeping
With the bank-down foam application method, the foam stream is directed: Correct Answer-onto an
object, allowing the foam to run down / onto the surface of the fuel.
Winches should be positioned: Correct Answer-as close to the object being pulled as possible
Which hydraulic tools may spread as much as 32 inches (800mm) apart? Correct Answer-spreaders
Which pneumatic tool can be used to vacuum loose soil from around victims buried in a trench collapse?
Correct Answer-air vacuum
Which method of moving water uses a primary water source located at a higher elevation than the
distribution system and delivers water to the system without the use of pumps? Correct Answer-gravity
system
What is NOT a reason a hose clamp is used? Correct Answer-to allow advancement of a charged hose line
down stairs
Where should the hose be connected on a fire dept pumper when being used for service testing hose
line? Correct Answer-to the discharges on the opposite side of the pump panel
What is the time span when presenting to young children? Correct Answer-15 minutes
The distribution system that provides circulating feed from all directions is called the _______. Correct
Answer-grid system
Which sprinkler systems are designed to quickly supply a large volume of water to the protected area?
Correct Answer-Deluge system
3 question to ask yourself during a vehicle incident size up. Correct Answer-1. are any utilities damaged?
2. Is there a need for additional resources?
3. Is there a fire / potential for a fire?
*Ages of the victims do not apply
Fog nozzles break down ____________ into tiny droplets. Correct Answer-foam solutions
What NFPA standard addresses fire inspection? Correct Answer-NFPA 1031
What is the first step in the basic four-step method of instruction? Correct Answer-preparation
Fixed-temp heat detectors are installed on the ______ of a room. Correct Answer-ceiling
When service testing fire hose, keep the hose testing area as _____ as possible when filling and
discharging air from the hose. Correct Answer-dry
The required air pressure in a dry-pipe system is usually about _____ psi (kPa) above the trip pressure
Correct Answer-20 (140)
Which pattern has limited capability for cooling hot gases? Correct Answer-solid stream
Which automatic alarm systems are used to protect large commercial and industrial buildings Correct
Answer-proprietary systems
What is a main type of liquified petroleum gas (LPG) ? Correct Answer-propane
[Show More]