Elevator Mechanic Questions and
Answers Graded A+
ASME ✔✔American Society of Mechanical Engineers
DOSH ✔✔Division of Occupational Safety and Health
LADBS ✔✔Los Angeles Department of Building and Safety
Alteration ma
...
Elevator Mechanic Questions and
Answers Graded A+
ASME ✔✔American Society of Mechanical Engineers
DOSH ✔✔Division of Occupational Safety and Health
LADBS ✔✔Los Angeles Department of Building and Safety
Alteration made to conveyance shall comply with ASME A17.1-204 Section ✔✔8.7
The seismic section of ASME A17.1-2004 and alterations made to conveyances must also
comply with this section ✔✔8.4
What must be submitted to the applicable Division Elevator office prior to beginning
construction or alterations on a conveyance
Title 8 Sec 3000 ✔✔Letter of Intent
When shall Category One Tests on conveyances be completed
Title 8 Sec 3141.6 ✔✔Once every 12 months
What shall be provided on all conveyances regardless of the existence of an emergency stop
switch
ASME A17.1-2004
2.27.1.2 ✔✔Audible signaling device
When are Hoistway door unlocking devices on all conveyances required
Title 8 Sec 3141.7
ASME A17.1-2004
2.12.6 ✔✔Prohibited
What section should Group IV platform lifts and stairway chairlifts shall comply with ✔✔ASME
A18.1-2003
When setbacks or projections exceed this number of inches, occur in the enclosure wall, the top
of the setback or projection shall be beveled at an angle not less than 75 degrees with the
horizontal
ASME A17.1-2004
2.1.6 ✔✔4 inches
At what height shall the hoistway enclosure of a Group IV elevator be Unperforated
ASME A17.1-2004
2.1.1.2.2 ✔✔79 inches
For elevators installed after June 5, 1947, there shall be installed in the pit of each elevator where
the pit extends below the sill of the pit access door a fixed vertical ladder. How many inches
below the sill?
ASME A17.1-2004
2.2.4.2 ✔✔35 inches
On a Group IV elevator, what is the minimum pit lighting illumination that should be provided at
the pit floor
ASME A17.1-2004
2.2.5.1 ✔✔10 fc (foot candles)
For Group IV elevators that are not fully enclosed, how high of protection should be provided on
the hoistway sides that are located 59 inches or less from elevator equipment in areas accessible
to other than elevator personnel
ASME A17.1-2004
2.2.1.3 ✔✔94.5 inches
Permanent means shall be provided to prevent the accumulation of what?, in the elevator pit
[Show More]