Education  >  QUESTIONS & ANSWERS  >  NCCER Level 1 Module 10 Basic Electrical Construction Drawings Already Passed (All)

NCCER Level 1 Module 10 Basic Electrical Construction Drawings Already Passed

Document Content and Description Below

NCCER Level 1 Module 10 Basic Electrical Construction Drawings Already Passed A cutaway view of a building or object is known as a(n)______. ✔✔Sectional drawing What is the total connected loa ... d of Circuit A-1 if each of the Type C lighting fixtures in the figure above has a total lamp and ballast load of 150VA? ✔✔1,200VA In which division of the MasterFormat is electronic safety covered? ✔✔Division 28 A section line on a drawing shows ✔✔The location of the section on the plan On electrical drawings, a solid line with a solid circle at the end indicates wiring______. ✔✔Turn down An electrical drafting line with a double arrowhead represents ✔✔A branch circuit homerun Which of the following are used in electrical drafting lines to show the number of circuits? ✔✔Arrowheads In dimension drawings, the dimensions written on the drawing are ✔✔The actual dimensions Which of the following is used in an electrical diagram to show wiring concealed in a floor? ✔✔A dashed line The architects scale is designed so that one inch equals one foot ✔✔False A circle with two parallel lines drawn through it is the symbol normally used for ______. ✔✔Duplex receptacles The NEC specifies one set of electrical drawing symbols that are used in all cases ✔✔False Which of the following letters in the figure above shows a dimension of 1'-6"? ✔✔B Dotted lines used to represent a branch circuit on a drawing mean that the wiring is to be ✔✔Exposed Which of the following letters in the figure above shows a dimension of 0'-3"? ✔✔C A branch circuit line or drawing that does not have slashes is assumed to have two conductors ✔✔True Which of the following letters in the figure above shows a dimension of 4'-9"? ✔✔A To meet general recommendations, a residential branch circuit rated for 2,400VA should have a connected lid of no more than ✔✔1,920VA Which of the following letters in the figure above shows a dimension of 1'-9"? ✔✔D Power riser diagrams are used to show the ✔✔Arrangement of electric service equipment The letter inside the triangles in the figure above represents _______. ✔✔The fixture types The symbols T, T2, and T3, in a typical motor starter schematic represent ✔✔Motor terminals According to the figure above, who is responsible for providing the electric service? ✔✔The utility company According to the figure above, where can information on Panel A be located? ✔✔Panelboard schedule Why is there a letter R next to the outlet boxes for the Type C lighting fixtures in the figure above? ✔✔Fixtures are recessed. How many lighting fixtures are connected to circuit A-3 in the figure above? ✔✔Eleven Type A and two Type B All of the following scales can be found on a triangular architect's scale, except______. ✔✔1- 3/4"=1'-0" Which of the following must be mounted so that no point along the wall line is more than 24" from a receptacle? ✔✔Receptacles located above countertops in kitchens Duplex receptacle outlets should be placed no more than _____. ✔✔12 feet apart A residential lighting branch circuit is to be loaded at no more than 80% of its capacity. If the circuit is operating at 120V and is rated at 12A, what is the maximum initial connected load? ✔✔1152VA Which of the following is indicated on a panelboard schedule? ✔✔Panel mains To determine wiring methods is compliance with the NEC, check construction methods and materials used by referring to the ____. ✔✔Wall sections Which of the following are used extensively to show the arrangement of electric service equipment? ✔✔One-line block diagrams The scale of the drawings is contained in the ______. ✔✔Title block Notes are used in power-riser diagrams to identify the number, size and _____. ✔✔Type of conductors The location of utility lines on the property are shown on the ______. ✔✔Site plan What is the number of conductors and the wire size specified for the feeder circuit supplying rooftop unit No. 1 in the power-riser diagram in the figure above? ✔✔Three No. 6 AWG Equipment schedules are part of the _____. ✔✔Electrical drawings Changes to the drawings will be noted in the _______. ✔✔Revision block An electrical drawing's title block includes the ______. ✔✔Address of the project [Show More]

Last updated: 2 years ago

Preview 1 out of 6 pages

Buy Now

Instant download

We Accept:

Payment methods accepted on Scholarfriends (We Accept)
Preview image of NCCER Level 1 Module 10 Basic Electrical Construction Drawings Already Passed document

Buy this document to get the full access instantly

Instant Download Access after purchase

Buy Now

Instant download

We Accept:

Payment methods accepted on Scholarfriends (We Accept)

Also available in bundle (1)

Click Below to Access Bundle(s)

NCCER BUNDLED EXAMS MULTIPLE VERSIONS (Module 1-10) QUESTIONS AND ANSWERS WITH VERIFIED SOLUTIONS

NCCER BUNDLED EXAMS MULTIPLE VERSIONS (Module 1-10) QUESTIONS AND ANSWERS WITH VERIFIED SOLUTIONS

By Nutmegs 2 years ago

$23

20  

Reviews( 0 )

$9.00

Buy Now

We Accept:

Payment methods accepted on Scholarfriends (We Accept)

Instant download

Can't find what you want? Try our AI powered Search

147
0

Document information


Connected school, study & course


About the document


Uploaded On

Feb 19, 2023

Number of pages

6

Written in

All

Seller


Profile illustration for Nutmegs
Nutmegs

Member since 4 years

607 Documents Sold

Reviews Received
77
14
8
2
21
Additional information

This document has been written for:

Uploaded

Feb 19, 2023

Downloads

 0

Views

 147

Document Keyword Tags


$9.00
What is Scholarfriends

Scholarfriends.com Online Platform by Browsegrades Inc. 651N South Broad St, Middletown DE. United States.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Scholarfriends · High quality services·