EPA 608 (TYPE II) Exam Questions and
answers, 100% Accurate. Rated A
When a new system has been assembled, the first thing to do is? - ✔✔-Pressurize the system with an
inert gas & leak check.
After installation of
...
EPA 608 (TYPE II) Exam Questions and
answers, 100% Accurate. Rated A
When a new system has been assembled, the first thing to do is? - ✔✔-Pressurize the system with an
inert gas & leak check.
After installation of a field-piped R-410A split heat pulp, the unit should first be? - ✔✔-Pressurized with
nitrogen then leak checked.
The EPA regulations require that any appliances containing more than 50 pounds of refrigerant (except
for commercial & industrial process refrigeration) must be repaired when the leak rate exceeds
_________ of the charge per year? - ✔✔-15%
R-410A requires recovery tanks rated for at least? - ✔✔-400 psig
After refrigerant liquid has been recovered from a system, any remaining vapor is? - ✔✔-Condensed by
the recovery system.
Your recovery/recycling machine has R-502 refrigerant in it. You now have to recover refrigerant from a
unit with R-22. What must be done before the R-22 refrigerant can be recovered/recycled? - ✔✔-
Recover as much R-502 from the recovery unit as possible, change filter, & evacuate.
In a refrigeration system with a TXV (or other type of throttling device), the component directly
following the condenser is the? - ✔✔-Receiver
When charging an R-410A system that uses a water-cooled condenser, you must first charge with vapor
to a pressure of at least________, before switching to liquid charging. - ✔✔-120 psig
Recovered refrigerant may contain what? - ✔✔-1.) Acids
2.) Moisture
3.) Oils
Your recovery/recycling machine has R-22 refrigerant in it. You now have to recover refrigerant from a
unit with R-410A. What must be done before your recovery unit can be used to recover R-410A? - ✔✔-
1.) The recovery unit must be EPA certified for use with R-410A.
2.) The recovery tank must be designed for the pressure of R-410A.
3.) The filter & lubricant in the recovery unit must be changed, & the recovery unit evacuated.
To recover liquid refrigerant, you must connect one hose to the? - ✔✔-Liquid Line.
The proper charging method for blended (non-azeotropic) refrigerants (400 Series) is to use a remove
the charge from the cylinder as a? - ✔✔-Liquid
Before using a recovery unit to remove a charge, what steps should be taken? - ✔✔-1.) Check service
valve positions.
2.) Check the oil level in the recovery unit.
3.) Evacuate recovery unit & recovery tank.
On refrigeration units that use an open compressor; the ________ is most likely to leak if the unit is not
used for several months. - ✔✔-The rotating shaft seal.
Noncondensables in a system cause? - ✔✔-Higher discharge pressure.
Heat Pumps that use R-410A should be leak checked with? - ✔✔-Pressurized Nitrogen.
A reciprocating compressor should not be energized when? - ✔✔-The discharge service valve is closed.
In a refrigeration system, the component directly following the evaporator is the? - ✔✔-Accumulator.
Manifold gauge set hoses should have self-sealing connectors or hand valves to? - ✔✔-Minimize the
release of refrigerant when the hoses are connected & disconnected.
The EPA regulations require that leaking commercial or industrial process refrigeration equipment must
be repaired when the leak rate exceeds _____ of the charge per year. - ✔✔-35%
Moisture is removed from a system by? - ✔✔-Using a filter drier.
Oil foaming usually occurs in the? - ✔✔-Compressor
R-410A is different from other ASHRAE 400 series non-azeotropic blends because? - ✔✔-R-410A
behaves as a near azeotropic refrigerant, & can be topped off.
With an air-cooled condenser on the roof of a building & the evaporator on the first floor, recovery
should first occur? - ✔✔-From the liquid line entering the evaporator.
A deep vacuum is usually measured in? - ✔✔-Microns.
Heat Pumps that use R-134A should be leak checked with? - ✔✔-Pressurized Nitrogen.
During the evacuation of a system that contains large amounts of moisture it may be necessary to
increase pressure in the system with ________, to counteract the freezing of the moisture. - ✔✔-
Nitrogen.
When under a deep vacuum, the motor winding of a hermetic refrigeration compressor? - ✔✔-Will be
damaged if energized.
When using recovery or recycling equipment that was manufactured AFTER November 15, 1993: you
must evacuate a system containing MORE than 200 pounds of CFC-12 to _______ before making a major
repair. - ✔✔-15 inches Hg vacuum
When inspecting a system for leaks, you should look for? - ✔✔-Traces of oil.
Refrigerant leaves the receiver of a s