Electrical Engineering > QUESTIONS & ANSWERS > Nerc Test Questions and Answers Latest 2022 (All)
Nerc Test Questions and Answers Latest 2022 According to Nerc Standards, an emergency interchange transaction can be exempt from tagging if it is less than_________________ ✔✔60 minutes A BA o... r LSE that requests an EEA 3 must complete and EEA 3 report and submit it to the RC within how many days ✔✔2 business days During restoration efforts load pick-ups should not exceed_____________ percentage of synchronized generation capacity ✔✔5% What are the two components that a system operator should be aware of for controlling frequency during a system restoration if they are in an islanded situation ✔✔load and generation What system was put in place to provide RC's with a mechanism to handle energy deficiencies? ✔✔Energy Emergency Alerts If due to a reliability event, an interchange transaction must be modified, how long does the Sink Balancing Authority have to modify the tag? ✔✔withing 60 minutes of the start of modification What is an example of a disturbance that has caused you system to become islanded? ✔✔Frequency Fluctuations What is an instance is which you use manual load shedding? ✔✔Continuous decline in frequency What actions should be implemented during a EEA 2 ✔✔Schedule emergency assistance, recall all non-firm exports, start all available generation What would be an appropriate situation for a system operator to shed load? ✔✔Transmission facility is overloaded, voltages are rapidly decaying, and no other situations are available If an RC issues you a directive to implement when should it be implemented? ✔✔Without delay, within 30 minutes Each Operating Authority should periodically practice________________ ✔✔Simulated emergencies If a Transmission Operator has an anticipated emergency condition, it shall inform_________________ ✔✔Its RC and any other potentially affected Transmission Operators How often shall the Transmission Operator and BA review and update each emergency plan___________ ✔✔Annually According to Nerc Standards, emergency plans must include interim provisions if it is expected to take more than how many minutes to implement the contingency plan for loss of primary control facility ✔✔60 Which EEA is used to announce the change in transmission service priority? ✔✔EEA 2 Who is the only entity that can declare an EEA? ✔✔Reliability Coordinator Who must a system operator receive approval from to manually shed load? ✔✔No one Automatic load shedding schemes should consider the following 3 things........ ✔✔frequency, the rate of frequency decay, the rate of voltage decay Blackstart capabilities should be verified by______________ ✔✔periodic testing Synchroscopes should be calibrated in_____________ ✔✔degrees What type of relay is relay 87? ✔✔Differential relay If Ace is -50 before a disturbance it must return to____________ ✔✔-50 The disturbance recovery period is__________ minutes after the start of of a reportable disturbance. ✔✔15 What are the 3 types of AGC? and what is AGC? ✔✔Constant Frequency, Constant Interchange, Tie-line Bias What type of relay is relay 21? ✔✔Dista [Show More]
Last updated: 2 years ago
Preview 1 out of 14 pages
Buy this document to get the full access instantly
Instant Download Access after purchase
Buy NowInstant download
We Accept:
NERC BUNDLED EXAMS QUESTIONS AND ANSWERS WITH VERIFIED SOLUTIONS
By Nutmegs 2 years ago
$16
9
Can't find what you want? Try our AI powered Search
Connected school, study & course
About the document
Uploaded On
Jan 14, 2023
Number of pages
14
Written in
This document has been written for:
Uploaded
Jan 14, 2023
Downloads
0
Views
140
In Scholarfriends, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.
We're available through e-mail, Twitter, Facebook, and live chat.
FAQ
Questions? Leave a message!
Copyright © Scholarfriends · High quality services·