Medical Studies > QUESTIONS & ANSWERS > Questions and Answers > University of Iowa - BME 2210 Homework3_solutions. (All)

Questions and Answers > University of Iowa - BME 2210 Homework3_solutions.

Document Content and Description Below

Homework 3: BME 2210 Due as a single PDF file ICON submission by F 1. Using Matlab, plot the following ultrasound pressure wave as a function where 5 neper/m, where neper is a dimensionless q... uantity, rad/s, and Submit your “.m” file as well as the resulting graph labeled appropriately. Plot of attenuated acoustic pressure wave 2. An ultrasound imaging system is used to create a B-mode image of a soft-tissue sample. We want an image that extends to a depth of 30 cm from the transducer. Assume that 175 A-mode lines are used to create the B-mode image. a) How much time is required to acquire the data for each A-mode line? b) What is the maximum possible B-mode image refresh rate, in frames per second? c) Using the same refresh rate calculated above, what is the maximum depth possible if all A-mode lines are acquired simultaneously? 3. Answer the following showing your work: a) If the attenuation coefficient of the heart muscle ??ℎ?? = 0.185 (???? ∙ ??????)-1, calculate the distance at which the signal amplitude of a 2-MHz ultrasound beam will be reduced by half traveling through heart muscle. b) You have two transducers available, a 25-MHz transducer and a 3-MHz transducer. Which transducer should you use to perform an echocardiogram, and why (show your work)? 4. An ultrasound beam incident at an angle of 15° from fat tissue into muscle tissue, calculate the angle of refraction using the table below? 5. Using the table above and in the figure shown below, the transducer is stimulated with a A B Fat Transducer short pulse resulting in a short burst of pressure traveling through the sequence of materials shown in figure. Assume that no echoes are returned at the transducer-tissue interface. The transducer is operating at 3 MHz frequency, measured from the transducer edge, A = 3 cm and B = 5 cm. Use specific sound speeds in the corresponding materials. a) Assuming perpendicular incidence and that the system is setup to equalize the amplitude of all the returned signals (don’t account for attenuation and reflection/transmittance at interfaces), sketch the timing of the first echoes (signals) received by the transducer from interfaces A, and B. b) Now accounting for attenuation and reflection/transmittance at interfaces calculate the actual amplitudes of the pulses from interfaces A and B relative to the incident amplitude. end [Show More]

Last updated: 2 years ago

Preview 1 out of 5 pages

Buy Now

Instant download

We Accept:

We Accept
document-preview

Buy this document to get the full access instantly

Instant Download Access after purchase

Buy Now

Instant download

We Accept:

We Accept

Reviews( 0 )

$13.00

Buy Now

We Accept:

We Accept

Instant download

Can't find what you want? Try our AI powered Search

112
0

Document information


Connected school, study & course


About the document


Uploaded On

Feb 19, 2021

Number of pages

5

Written in

Seller


seller-icon
Kirsch

Member since 5 years

941 Documents Sold

Reviews Received
111
37
8
4
28
Additional information

This document has been written for:

Uploaded

Feb 19, 2021

Downloads

 0

Views

 112

Document Keyword Tags


$13.00
What is Scholarfriends

In Scholarfriends, a student can earn by offering help to other student. Students can help other students with materials by upploading their notes and earn money.

We are here to help

We're available through e-mail, Twitter, Facebook, and live chat.
 FAQ
 Questions? Leave a message!

Follow us on
 Twitter

Copyright © Scholarfriends · High quality services·